Technical Information
138
G 1xxx/G 2xxx
3.9 Fault
Indications
Model Fault
Indication
G x17x, G x18x
At the end of the program cycle, with the door open, all program
LEDs flash.
The buzzer sounds for two minutes.
“SaniWash” LED flashes, e.g., 1x quickly for F01.
“Intake/Drain” LED may flash.
G 1262
The optical indicator flashes.
The buzzer sounds.
All LEDs are flashing fast when the door is open.
The time display shows FXX (e.g., F01).
G x47x
The optical indicator flashes.
The buzzer sounds.
All LEDs are flashing fast when the door is open.
The time display shows FXX (e.g., F01).
“Intake/Drain” LED may flash.
G 2020, G 2120, G 214x,
G 2150
“Wash/Rinse”, “Drying” and “End” LEDs flash simultaneously at
the end of the program. "Intake/Drain" LED may flash.
Flash pattern during fault check: "Rinse" LED, e.g., once rapidly
at intervals (for F01).
G 1202, G 2630, G 2670,
G 2732, G 283x, G 2872
At the end of the program, the display reads, e.g.,
Technical
fault F01. Call the Service Department
(or
Water inlet fault
or
Drainage fault
). The buzzer is activated for 2 minutes.
G 2420, 243x
The "Rinse", "Drying" and "End" LEDs flash simultaneously.
The time display shows FXX (e.g., F01).
The buzzer sounds for 2 minutes.
“Intake/Drain” LED may flash.
Table 080-3:
Model-Specific
Fault Indications
3.10
Fault Indication in Models with Software ID -769
Software ID -769 has the following distinctive features:
1.
Sensor system fault codes F87, F88
When the turbidity sensor fault code
F88
is registered, the sensor
softener fault code
F87
is also saved. This happens even if the sensor
softener is functioning correctly.
The reverse is not true. If the sensor softener fault code
F87
is saved,
there is a fault at the sensor softener and fault code
F88
will not
automatically be registered.
2.
Salt warning display fault.
If the
Salt
warning indicator has lit during a program in operation and
the program is interrupted by switching the power supply off, then on,
the
Salt
LED is no longer lit. The display only lights again when a new
dishwashing program is started.
3.
LED indication interrupted after switching unit off and on at the
power source (Integrated models).
If a program in operation is interrupted by switching the power supply
Содержание ADVANTA G 2170
Страница 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Страница 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Страница 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Страница 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Страница 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Страница 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Страница 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Страница 123: ...Technical Information 123 G 1xxx G 2xxx 080 Electronic Novotronic and Touchtronic Incognito Navitronic ...
Страница 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Страница 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...