Technical Information
137
G 1xxx/G 2xxx
3.8
Fault Code Summary
Note:
Not all fault codes apply to all model numbers.
Fault Code
Possible Fault
F00
No fault registered
F01
(see Section 080-3.11)
Water/heating NTC or leads short-circuited
F02
(see Section 080-3.12)
Water/heating NTC or leads open-circuited
F11
(see Section 080-3.13)
Drainage fault
F12
(see Section 080-3.14)
Water intake fault at start of step
F13
(see Section 080-3.15)
Water intake fault at end of step
F14
(see Section 080-3.16)
Water intake fault: Heater pressure switch
F15
(see Section 080-3.17)
Water intake fault: Hot water
F18
(see Section 080-3.18)
Flow meter stationary state monitor
F19
(see Section 080-3.19)
Flow meter stiff and not turning freely
F24
(see Section 080-3.20)
Heater relay contact
F25
(see Section 080-3.21)
Target temperature fault
F26
(see Section 080-3.22)
Boiling protection
F32
(see Section 080-3.23)
Door lock does not close
F33
(see Section 080-3.24)
Door lock does not open
F36
(see Section 080-3.25)
Door lock switch defective
F40
(see Section 080-3.26)
Electronic fault
F42
(see Section 080-3.27)
Line frequency registration fault
F47
(see Section 080-3.28)
Faulty electronic interface (between BAE & SLT)
F51
(see Section 080-3.29)
Heater pressure switch
F52
(see Section 080-3.30)
Heater pressure switch has reset during heating
F53
(see Section 080-3.31)
Speed sensor fault
F63
(see Section 080-3.32)
Slide shutter fault
F67
(see Section 080-3.33)
Circulation pump speed too low
F68
(see Section 080-3.34)
Circulation pump operating after switch-off
F69
(see Section 080-3.35)
Circulation pump blocked
F70
(see Section 080-3.36)
Float switch fault
F78
(see Section 080-3.37)
Circulation pump fault
F79
(see Section 080-3.38)
Circulation pump interaction fault
F84
(see Section 080-3.39)
Slide shutter positioning fault
F85
(see Section 080-3.40)
Slide shutter signal change fault
F86
(see Section 080-3.41)
Lid contact - salt
F87
(see Section 080-3.42)
Sensor softener fault
F88
(see Section 080-3.43)
Turbidity sensor fault
F91
(see Section 080-3.44)
Load size registration inactive
Table 080-2:
Fault Code Summary
Содержание ADVANTA G 2170
Страница 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Страница 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Страница 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Страница 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Страница 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Страница 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Страница 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Страница 123: ...Technical Information 123 G 1xxx G 2xxx 080 Electronic Novotronic and Touchtronic Incognito Navitronic ...
Страница 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Страница 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...