Program settings
106
Activating con-
ductivity measur-
ing
Conductivity measuring is activated individually for each program.
Conductivity is measured in the final rinse phase.
...
Conductivity Limit
Conductivity Limit
Water intake
Water drainage
-
Water intake
The electrical conductivity of the water after water intake during fi-
nal rinse phase is measured.
-
Water drainage
The electrical conductivity of the water at the end of the final rinse
phase is measured.
Select an option using the
and
arrow buttons.
Press
OK
to save the setting.
Following selection a maximum limit value for electrical conductivity
must be set.
Setting limit val-
ues
The limit values for
Water intake
and
Water drainage
are set individu-
ally.
...
Conductivity Limit
Water intake
and/or
Water drainage
Set
Water intake
--
µS/cm
(5 - 200 µS/cm)
--
µS/cm
(5 - 200 µS/cm)
Water drainage
The limit values are set in increments of 1. The possible range is
shown in the bottom line of the display.
Use the arrow buttons
(higher) and
(lower) to set the limit
value.
Press
OK
to save the limit value.