Technical data
77
Height
2495 mm
Width
1150 mm
Depth
990 mm
Wash chamber dimensions:
Height
Width
Depth
680 mm
640 mm
800 mm
Weight (net)
550 kg
Maximum floor load
8 kN/m
2
Voltage, rated load, fuse rating
See data plate
Compressed air connection:
technical
600–750 kPa
Steam connection
250–1000/140–180 kPa/°C
Water connection water temperature:
Cold water/steam condenser
Hot water/demineralised water*
Max. 20 °C
Max. 65 °C
Water connection pressure
Max. 200–1000 kPa excess pressure
Operation:
Ambient temperature
Relative humidity maximum
linear decreasing to
5 °C – 40 °C
80 % for temperatures up to 31 °C
50 % for temperatures up to 40 °C
Storage and transportation conditions:
Ambient temperature
Relative humidity
Air pressure
-20 °C – +60 °C
10–85 %
500–1060 hPa
Altitude above sea level
Up to 1500 m
Protection category (according to IEC 60529)
IP 20
Soiling level (according to IEC/EN 61010-1)
P2
Overvoltage category (according to IEC 60664)
II
Noise level in dB (A),
sound pressure LpA during cleaning and drying
phases
< 70
Test certification
VDE, radio and television suppressed
marking
2006/42/EC Machinery Directive
Manufacturer address
Miele & Cie. KG, Carl-Miele-Str. 29,
33332 Gütersloh, Germany