CLOCK
REV.0.03_COD.610078_A4
Page 41
10.
CLOCK
The control has a real-time clock.
Time reading is also used when recording historical data.
11.
HISTORICAL DATA
During the working cycle, the machine memorizes all working data of the wash cycles that
have been performed on a card.
The card is able to record the fields described below for up to max. 200 cycles in the
permanent memory.
The fields given in the example below are recorded for each cycle:
DATE
START TIME
PROGRAM
MAX °F (°C)
HOLD >185°F
(85°C)
FAULTS
12/12/2018 12.00
Short 140°F
(60°C)
60 seconds
01
12/12/2018
13.05
Standard
140°F (60°C)
180 seconds
01
When 95% of the memory is full the dump memory message appears on the display.
To deactivate the recurring message follow the steps below.
Hold PRG
pressed for 5 seconds.
Use buttons P1
and P2
to scroll through the menu to the following options.
Each value must be confirmed individually by pressing START
:
'Setting'
"Parameter"
Entering password
“System”
Select one of the following parameters using buttons P1
and P2
:
o
Parameter 1.16
Confirm selection by pressing START
.
Select one of the following options with buttons P1
and P2
:
o
0 = No warning
If the memory is full, the oldest report is overwritten
o
1 = Warning
o
2 = Warning and it is not possible to start a cycle
Confirm selection by pressing START
.
Exit the menu by pressing STOP
.