CONTROL PANEL AND SYMBOLS USED
REV.0.03_COD.610078_A4
Page 25
6.
CONTROL PANEL AND SYMBOLS USED
The control panel with liquid crystal display is illustrated in the image.
This panel makes the machine easy to use, as it indicates the cycle phases in progress and
the temperature reached during each cycle phase; besides, it displays any error messages.
6.1
Buttons
The buttons of the glass display are touch-sensitive and backlit (LED). There are 8 buttons
available with the following functions:
BUTTON
DISCRIPTION
A
STOP
One press for interrupting a program.
The display advices the disinfection lack and the “manual
stop” message appears, the door remains
locked and, if
necessary, it indicates the temperature inside the chamber.
By pressing START, the machine restarts the cycle execution
from the point, in which it had been stopped.
Two presses for canceling a program.
The machine returns to the stand-by condition and the door
is
unlocked.
(cancel)
For canceling a process.
B
START
Starting a program.
(confirm)
For selecting or confirming entries in the user interface.
C
P+
For accessing the list of all additional programs.
D
PRG
The menu incorporates all relevant functions.
During standby: Press the button for 5 seconds to access the menu.
E
P1
Short program
(down)
For navigating within the display.
F
P2
Standard program
(up)
For navigating within the display.
G
P3
Intensive program
H
DRY
Drying function.
Before starting a program, it is possible to add additional drying time
or to deactivate the drying function.
The standard drying setting is 20 minutes on each program.
By pressing the button once, an additional 5 minutes is added to the
drying time, for a total drying time of 25 minutes.
By pressing the drying button twice, the drying step will be
deactivated.
B
C
D
E
F
G
H
Display
A