INSTALLATION
REV.0.03_COD.610078_A4
Page 19
3.6
Connecting the drain hose
The drain hose connection should be checked carefully.
The machine is equipped with a drain hose with a diameter indicated on the
installation plan.
The choice of materials relating to the ventilation circuit for drainage operations must
take into account the same requirements as for piping that comes into direct contact
with drain fluids; it must be taken into consideration that these may give off harmful
(corrosive, toxic, etc.) vapors that may involve the output/input point of the duct.
CAUTION
If the drain system is clogged take great care when processing the water
and avoid contact with hands, eyes, etc., in the case of contact rinse the
parts concerned with plenty of water.
The drain hose is connected to the sewer network in the following manner:
Identify the drain pipe and relative fittings, and assemble them.
Make sure the seal gasket is installed correctly.
Identify the drain manifold and connect the hose via the union and ring nut. Tighten
the ring nut firmly.
Insert the drain hose and clamp it in place.
Insert the other end of the hose into the drain unit, installing it properly and locking it
in position.
It is necessary to follow these instructions for drain connection:
Drain hose must be connected by using a clamp.
Drain hose must not present angles or irregular curving in its course.
Drain point must be placed at the same height of the machine drain point or on the
floor.
Carefully follow these instructions as a wrong drain connection can cause the block of
machine.
The diameter of main drain must be as indicated on the installation plant.
Avoid drain pipe extension.
ATTENTION
Drainage must be done following international rules.
The manufacturer cannot be held responsible if an inaccurate if
inaccurate machine use causes pollution.
If the drain system is clogged take great care when processing the water
and avoid contact with hands, eyes, etc. In the case of contact rinse the
parts concerned with plenty of water.
When the machine is connected to an exhaust ventilation system, the
drain hose should be positioned outside the building, protected from any
animal access, and make sure that it not causes any hazard.