The table below will help you troubleshoot test messages. If troubleshooting does not solve the problem, call Midtronics
Customer Service at 1.800.776.1995.
MESSAGE
EXPLANATION
System Noise
Detected
The GR8 has detected computer, ignition noise, or parasitic drain, and will attempt to retest. Make
sure all vehicle loads are off, doors are closed, and the ignition is in the off position. The GR8 will
automatically retest when it no longer detects system noise. If the message reappears:
•
You may be testing too close to a noise source, such as a charger or other high-current
device. If so, move away and retest.
•
If you are unable to find the source of the noise, fully charge the battery and retest. If the
message appears after recharging, test the battery out of the vehicle.
•
Disconnect the battery cables and retest.
Unstable Battery
Detected
A battery that is weak, or that has just been charged, may retain enough electrical activity to
be detected by the GR8 and will adversely affect the test results. A fully charged battery should
stabilize quickly, after which the GR8 will automatically retest. Weak batteries should be charged
and retested. If the battery is fully charged, check the clamp connections.