4
PRODUCT PROGRAMMING
Midian’s SVR-1-IC1 is programmed via Midian’s KL-4F programming interface and the MPS software. Please
reference the KL-4F manual for setup instructions of the MPS software and the KL-4F hardware. From the
product selection screen in the software, select the SVR-1-IC1 from the list and click OK.
Set the parameters of the software to fit the application. If any clarifications on a feature are required, move the
mouse cursor over the feature name until the question mark appears and right click, a definition of the feature will
be shown.
After entering the parameters, save the file by going to File - Save As. Enter the file name in the File Name block
and click Save. Saving the file will allow for quick and easy reprogramming of units.
Programming:
Plug the board onto the IC1 connector on the KL-4F. Press and hold the power button on the KL-
4F and click “Program Unit” in the MPS software. The ACK LED on the KL-4F will faintly flash if programmed
successfully.
Reading:
Plug the board onto the IC1 connector on the KL-4F. Press and hold the power button on the KL-4F
and click “Read Unit” in the MPS software.
Note: Upon power up the unit will be awake for 15 seconds before going into Power Save mode.
After programming or reading the SVR-1 turn off the unit for 3 seconds and then turn back on.