DEFAULT VALUES OF INDOOR UNITS
Table 2—Default Values of Indoor Units
Description
Remote Code
Cassette
Ducted
Console
Auto-Start Function
F1
ON
ON
ON
Heating Temperature Compensation
F2
6C
6C
0C
Anti-Cold Air Function
F3
NORMAL
NORMAL
NORMAL
Indoor Fan Motor Speed Control after Set Temperature is Reached
F4
SET SPEED
SET SPEED
SET SPEED
Louver Angle Memory Function
F5
N/A
N/A
N/A
Heating Only or Cooling and Heating Setting
F6
CH
CH
CH
Cooling Temperature Compensation
F7
-2C
-2C
-2C
Refrigerant Leakage Detection
F8
ON
ON
ON
Cleaning Filter Reminder
F9
OFF
OFF
OFF
Filter Replacement Reminder
E1
OFF
OFF
OFF
Lowest Temperature Setting
E2
17C
17C
17C
Highest Temperature Setting
E3
30C
30C
30C
Special Anti-Cold Air Function Setting
E4
N/A
N/A
N/A
Priority Setting of Heating or Cooling (Multi-Zone Systems only)
E5
H
H
H
Network Address Setting
E6
N/A
N/A
N/A
Capacity Code Selection
E7
N/A
N/A
N/A
Twins Setting
E8
N/A
N/A
N/A
Static Pressure Setting
E9
N/A
0
N/A
POINT CHECK FUNCTION
Press LED
on the remote controller three times and then press SWING
three times within 10 seconds, the buzzer rings for 2 seconds and the air
conditioner enters the information enquiry status. Next, press LED
to search the information. Press SWING
to search the remaining information.
When the air conditioner enters the enquiry information status, it displays the code name in 2 seconds (see Table 3).
Table 3—Information Codes
Enquiry Information
Displaying Code
Meaning
T1
T1
Return temperature
T2
T2
Indoor Coil temperature
T3
T3
Outdoor Coil temperature
T4
T4
Outdoor Air temperature
T2B
Tb
Indoor Coil Leaving temperature
TP
TP
Compressor Discharge temperature
TH
TH
IPM Heatsink temperature
Targeted Frequency
FT
Targeted Frequency
Actual Frequency
Fr
Actual Frequency
Indoor fan speed
IF
Indoor fan speed
Outdoor fan speed
OF
Outdoor fan speed
EXV opening angle
LA
EXV opening angle
Compressor continuous running time
CT
Compressor continuous running time
Causes of compressor stop
ST
Causes of compressor stop
Reserve
A0
Reserve
A1
Reserve
.b0
Reserve
.b1
Reserve
.b2
Reserve
.b3
Reserve
.b4
Reserve
.b5
Reserve
.b6
Reserve
.dL
Reserve
Ac
Reserve
Uo
Reserve
Td