background image

        
         Under this condition, the air conditioner will stop heating operation and start defrosting 
         automatically.
         The time to defrost may vary from 6 to 10 minutes according to the outdoor temperature
         and the amount of frost buildup on the outdoor unit.
2. A white mist coming out from the indoor unit
         A white mist may generate due to a large temperature difference between air inlet and 
         air outlet on COOL mode in an indoor environment that has a high relative humidity.
         A white mist may generate due to moisture generated from defrosting process when the
         air conditioner restarts in HEAT mode operation after defrosting.
3. Low noise of the air conditioner
         You may hear a low hissing sound when the compressor is running or has just stopped
         running. This sound is the sound of the refrigerant flowing or coming to a stop.
         You can also hear a low "squeak" sound when the compressor is running or has just 
         stopped running. This is caused by heat expansion and cold contraction of the plastic 
         parts in the unit when the temperature is changing.
         A noise may be heard due to louvre restoring to its original position when power is first 
         turned on.
4. Dust is blown out from the indoor unit.
    This is a normal condition when the air conditioner has not been used for a long time or 
    during first use of the unit.
5. A peculiar smell comes out from the indoor unit.
    This is caused by the indoor unit giving off smells permeated from building material, from
    furniture, or smoke. 
6. The air conditioner turns to FAN only mode from COOL or HEAT (reverse cycle models
    only) mode.
    When indoor temperature reaches the temperature setting on air conditioner, the compressor
    will stop automatically, and the air conditioner turns to FAN only mode. The compressor will
    start again when the indoor temperature rises on COOL mode or falls on HEAT mode
    (reverse cycle models only) to the set point.

        
7. Dripping water may generate on the surface of the indoor unit when cooling in a high 
    relatively humidity (relative humidity higher than 80%). Adjust the horizontal louvre to the
    maximum air outlet position and select HIGH fan speed.
8. Heating mode (Reverse cycle models only)
    The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
    during heating operation. When the outdoor temperature falls, heat drawn in by the air 
    conditioner decreases accordingly. At the same time, heat loading of the air conditioner 
    increases due to larger difference between indoor and outdoor temperature. If a comfortable
    temperature can't be achieved by the air conditioner, we suggest you use a supplementary
    heating device.
9. Auto-restart function 
    After the power cut-off, the air conditioners can automatically restore the previous function setting.

10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
      Disconnect the unit with power and then re-connect the unit with power again. Push the 
      ON/OFF button on the remote controller to restart operation.

10

Содержание MSV1-09HRN1

Страница 1: ...er please read this manual carefully and keep it for future reference SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future referen...

Страница 2: ...ou review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of this unit Contact the installer for install...

Страница 3: ...fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire a...

Страница 4: ...ces food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the...

Страница 5: ...he possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving preci...

Страница 6: ...LAY indication lamp Displays the current setting temperature when the air conditioner is in operation When AUTO CLEAN feature is activated it displays OPERATION indication lamp This lamp illuminates w...

Страница 7: ...ate under FAN ONLY mode at LOW fan speed for 30 minutes and then stop the operation and the unit turn off For cooling heating models the air conditioner will operate FAN ONLY mode at Low fan speed 13...

Страница 8: ...de To set the vertical air flow direction Perform this function while the unit is in operation Press the SWING button on the remote control to move the louvre and press it again when the louvre gets t...

Страница 9: ...estricted air flow area Do not operate unit with horizontal louvre in closed position When the air conditioner is connected to power initial power the horizontal louvre may generate a sound for 10 sec...

Страница 10: ...on depending on what temperature you have selected and the room temperature The air conditioner will control room temperature automatically round the temperature point set by you If the AUTO mode is u...

Страница 11: ...iving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT reverse cycle models only mode When indoor temperature reaches...

Страница 12: ...shing powder or other similar solvent to clean the unit Thinner No Household Drain Cleaner Cleaning and Maintenance No 11 Cleaning the Air filter CAUTION Turn the system off before cleaning The air fi...

Страница 13: ...air outlet or inlet is blocked Check before operate the unit after a long time unused 3 Remove the AIR FILTER from the indoor unit Clean the AIR FILTER once two weeks Clean the AIR FILTER with a vacuu...

Страница 14: ...time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperatur...

Страница 15: ...CS369 U 2200019091...

Отзывы: