background image

2

To prevent injury to the user or other people and property damage, the following instructions 
must be followed.
Incorrect operation due to ignoring of instructions may cause harm or damage. The 
seriousness is classified by the following indications.

Safety Precautions

This symbol indicates the possibility of death or serious injury.

Meanings of symbols used in this manual are as shown below.

!

!

WARNING

Always do this.

Never do this.

!

CAUTION

This symbol indicates the possibility of injury or damage to property.

Plug in power plug 
properly.

Do not modify power cord
length or share the outlet
with other appliances. 

Always ensure effective
earthing.

Unplug the unit if strange
sounds, smell or smoke
comes from it.

Keep firearms away.

Ventilate room before operating air
conditioner if there is a gas leakage from
another appliance.

   Otherwise, it may cause electric
   shock or fire due to excess heat 
   generation.

  It may cause electric shock or 
  fire due to heat generation.

  No earthing may cause electric 
  shock.

  It may cause fire and electric
  shock.

  It may cause fire.

  It may cause explosion, fire and, burns.

  It may cause electric shock or fire
  due to heat generation.

  It may cause electric shock.

  It may cause failure of machine
  or electric shock.

  It may cause fire and electric 
  shock.

  It may cause fire and electric 
  shock.

  It may cause electric shock or fire.
  If the power cord is damaged, it 
  must be replaced by the manufac-
  turer or an authorised service 
  center or a similarly qualified per-
  son in order to avoid a hazard.

  This could damage your health.

  No installation may cause fire
  and electric shock.

  It may cause electric shock.

   It may cause an explosion or fire.

  It may cause failure and electric shock.

Do not operate or stop the
unit by inserting or pulling 
out the power plug.

Do not operate with wet
hands or in damp 
environment.

Do not allow water to run
into electric parts.

Do not use the socket if it is
loose or damaged.

Do not use the power cord
close to heating appliances.

Do not damage or use an 
unspecified power cord.

Do not direct airflow at 
room occupants only.

Always install circuit
breaker and a dedicated
power circuit.

Do not open the unit
during operation.

Do not use the power cord near 
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.

Do not disassemble or modify unit.

!!

!!

!!

!!

!!

WARNING

!

!!

Содержание MSV1-09HRN1

Страница 1: ...er please read this manual carefully and keep it for future reference SPLIT TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future referen...

Страница 2: ...ou review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of this unit Contact the installer for install...

Страница 3: ...fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire a...

Страница 4: ...ces food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the...

Страница 5: ...he possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving preci...

Страница 6: ...LAY indication lamp Displays the current setting temperature when the air conditioner is in operation When AUTO CLEAN feature is activated it displays OPERATION indication lamp This lamp illuminates w...

Страница 7: ...ate under FAN ONLY mode at LOW fan speed for 30 minutes and then stop the operation and the unit turn off For cooling heating models the air conditioner will operate FAN ONLY mode at Low fan speed 13...

Страница 8: ...de To set the vertical air flow direction Perform this function while the unit is in operation Press the SWING button on the remote control to move the louvre and press it again when the louvre gets t...

Страница 9: ...estricted air flow area Do not operate unit with horizontal louvre in closed position When the air conditioner is connected to power initial power the horizontal louvre may generate a sound for 10 sec...

Страница 10: ...on depending on what temperature you have selected and the room temperature The air conditioner will control room temperature automatically round the temperature point set by you If the AUTO mode is u...

Страница 11: ...iving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT reverse cycle models only mode When indoor temperature reaches...

Страница 12: ...shing powder or other similar solvent to clean the unit Thinner No Household Drain Cleaner Cleaning and Maintenance No 11 Cleaning the Air filter CAUTION Turn the system off before cleaning The air fi...

Страница 13: ...air outlet or inlet is blocked Check before operate the unit after a long time unused 3 Remove the AIR FILTER from the indoor unit Clean the AIR FILTER once two weeks Clean the AIR FILTER with a vacuu...

Страница 14: ...time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Replace the battery Wait or cancel timer setting Set temperatur...

Страница 15: ...CS369 U 2200019091...