HOW THE AIR CONDITIONER WORKS
The following events may occur during normal operation.
1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3 minutes after it stops.
Anti-cold air (Reverse cycle models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger
is in one of the following three situations and the set temperature has not been reached.
A) When heating has just starting.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Reverse cycle models only).
Defrosting (Reverse cycle models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature
is low and humidity is high resulting in lower heating efficiency of the air conditioner.
.
Operation tips
AUTOMATIC OPERATION
When you set the air conditioner in AUTO mode, it will
automatically select cooling, heating(cooling/heating
models only), or fan only operation depending on what
temperature you have selected and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
If the AUTO mode is uncomfortable, you can select
desired conditions manually.
SLEEP OPERATION
When you push SLEEP button during cooling, heating
(cooling only type without),or AUTO operation , the air
conditioner will automatically increase (cooling) or
decrease (heating) 1
per hour. The set temperature
will be steady 2 hours later. The fan speed will be
automatically controlled .
Note: The unit will be automatically turned off after 7
hours when on SLEEP operation.
DRYING OPERATION
The dry mode will automatically select the drying
operation based on the difference between the set
temperature and the actual room temperature.
The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or
fan only. The fan speed is LOW.
Cooling
Cooling
Time
DRYING operation
Room
temperature
set temperature
Cooling
Fan only
Fan only
Press Sleep button
1
1
1 hour
1 hour
Set
Temperature
Cooling
Press Sleep button
1
1
1 hour
1 hour
Set
Temperature
Heating
9
Содержание MSV1-09HRN1