33
Auto fan at cooling mode:
3
T-Ts
Room temp. up
Room temp. down
5
High fan
Low fan
1
Mid. fan
Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )
TE5
T
EVAP. temp. up
EVAP. temp. down
TE6
Compressor and
outdoor fan on
Compressor and outdoor
fan off (after 5 mins)
11.6
Dehumidifying mode
11.6.1
The 4-way valve is off in dehumidifying mode
11.6.2
Compressor and Indoor Fan actions in dehumidifying mode
11.6.3
0
TA-TS
2
C
B
A
Block
Indoor
Fan
Compressor and Outdoor Fan
LOW
ON 6minutes
BREEZE OFF 4minutes
LOW
ON 5minutes
BREEZE OFF 5minutes
LOW
ON 4minutes
BREEZE OFF 6minutes
A
B
C
Repeat on and off cycle.
11.6.4
Low room temperature protection:
When room temperature decreases to below 10
℃
, compressor and outdoor fan will stop(indoor fan is Breeze). Dehumidifying
operation will be resumed when room temperature restores to over 13
℃
.
11.6.5
At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode.
11.6.6
At dehumidifying mode, the action of fans of indoor is the same as that of air-only mode.
All manuals and user guides at all-guides.com
all-guides.com
Содержание MSQ-07CR
Страница 9: ...Service manual 6 3 2 Outdoor unit MSQ 07 09C H R All manuals and user guides at all guides com...
Страница 10: ...Service manual 7 MSQ 12C H R All manuals and user guides at all guides com...
Страница 17: ...Service manual 14 MSQ3 07HR MSQ3 09HR MSQ3 12HR MSQ3 12HR All manuals and user guides at all guides com...
Страница 18: ...Service manual 15 All manuals and user guides at all guides com...