DM16-01.01.23en
Kids Star Inverter
Service manual
25
valve’s service port immediately
If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the air
conditioner before disconnecting the hose.
6). Mounted the valve stem caps and the service port
Use torque wrench to tighten the service port cap to a torque of 18N.m.
Be sure to check for gas leakage.
Содержание MOA01-09HFN1
Страница 10: ...Kids Star Inverter DM16 01 01 23en 10 Service manual For MSEAAU 09HRFN1 SB MSEABU 12HRFN1 SB...
Страница 12: ...Kids Star Inverter DM16 01 01 23en 12 Service manual 4 2 Outdoor Unit...