7.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas Liquid
MSEAAU-09HRFN1(SB) + MOA01-09HFN1
3/8’’
(
Ф
9.52)
1/4’’
(
Ф
6.35)
5 10
25
15
MSEABU-12HRFN1(SB) + MOB01-12HFN1
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.