11.1 Indoor Unit Error Display
Display LED
STATUS
E0
Indoor unit EEPROM parameter error
E1
Indoor / outdoor units communication error
E3
Indoor fan speed has been out of control
E60
Indoor room temperature sensor T1 open circuit or short circuit
E61
Evaporator coil temperature sensor T2 open circuit or short circuit
PL
Refrigerant leakage detection
E53
Outdoor ambient temperature sensor T4 open circuit or short circuit
E52
Condenser coil temperature sensor T3 open circuit or short circuit
E54
Compressor discharge temperature sensor TP open circuit or short circuit
E51
Outdoor unit EEPROM parameter error
E7
Outdoor fan speed has been out of control
EA
Reading Indoor unit EEPROM parameter error
Eb
Indoor PCB /Display board communication error
EF
Intelligent eye malfunction
P0
IPM malfunction or IGBT over-strong current protection
P1
Over voltage or over low voltage protection
P2
High temperature protection of IPM module or compressor top
P4
Inverter compressor drive error