R410A Mini Split Chiller 50Hz
MCAC-UTSM-2014-01
64
1) Setting water temperature: under main page directly press the
“▲”
or
“▼”
to adjust the water
temperature, or press
“
Setting
”
key to enter and then press
“▲”
or
“▼”
to adjust. At that time the
LCD will display
“
Setting temperature
”
and
“
Water temperature parameter
”
, as the following display.
Query water temperature setting: press the
“
”
or
“
▲
”
key under
the main page to query the set water temperature numerical value.
2) Timing setting: can set 3 timing periods on the wired controller:
Timer 1, Timer 2, Timer 3, and then control the main unit to ON and
OFF in different periods. Setting method: press “Setting” key under
main page twice to enter timing setting. At that time the LCD will
display as the following:
1
TIMER
ON
This time the hour of the clock will flash, it means the current setting is the hour of Timer 1
“
On
”
, press the
“▲”
or
“▼”
to adjust, press
“
▲
”
key when finished, and then the minute of the clock will flash, it means
the current setting is the minute of Timer 1
“
On
”
, press the
“▲”
or
“▼”
to adjust, press
“
▲
”
key
when finished, the LCD will display as the following:
1
TIMER
OFF
This time the hour of the clock will flash, it means the current setting is the hour of Timer 1
“
Off
”
, press the
“▲”
or
“▼”
to adjust, press
“
▲
”
key when finished, and then the minute of the clock will flash, it means
the current setting is the minute of Timing 1
“
Off
”
, press the
“▲”
or
“▼”
to adjust, press
“
▲
”
key
when finished, the LCD will display as the following:
TIMER
ON
At this time the hour of the clock will flash, it means the current setting is the
hour of the Timer 2 “On”, and
the follow setting method will be the same of the Timer 1. Similarly, the setting of Timing 3 is the same with
this method. After setting, press “OK” key or wait for 7 seconds then the setting to be effective, and the LCD
will display the effective timing information, as the following display:
Содержание MGA-D10/N1
Страница 13: ...MCAC ATSM 2014 01 R410A Mini Split Chiller 50Hz 13 8 Service Space...
Страница 15: ...MCAC ATSM 2014 01 R410A Mini Split Chiller 50Hz 15 10 Wiring Diagrams 10 1 MGA D10 N1...
Страница 16: ...R410A Mini Split Chiller 50Hz MCAC ATSM 2014 01 16 10 2 MGA D12 N1 10 3 MGA D14 SN1 MGA D16 SN1...
Страница 32: ...R410A Mini Split Chiller 50Hz MCAC ATSM 2014 01 32 16 2 MGA D12 N1 Matched water pump box CE SBX N1 01A...
Страница 34: ...R410A Mini Split Chiller 50Hz MCAC ATSM 2014 01 34 16 3 MGA D14 SN1 Matched water pump box CE SBX SN1 01...
Страница 36: ...R410A Mini Split Chiller 50Hz MCAC ATSM 2014 01 36 16 4 MGA D16 SN1 Matched water pump box CE SBX SN1 01A...