Installation details
5.1 Installation place
5.1.1 Indoor Unit
a.
A place which provides the spaces around the indoor unit as required above in the
diagram.
b.
A place where is no obstacle near the inlet and outlet area.
c.
A place which can bear the weight of the indoor unit.
d.
A place which allows the air filter to be removed downward.
e.
A place where the reception range is not exposed to direct sunlight.
f.
In the center of the room where possible.
5.1.1.1 Please stand the unit in hard and flat ground;
Please reserve space for installation and maintenance.
5.1.1.2 Please check the elevation difference between the indoor unit and the outdoor unit, the length of
the refrigerant pipe, and the curved places (bend) of the pipe are no more than the following numbers:
Elevation difference: no more than 10M (if the elevation difference between indoor and outdoor unit
is more than 10 meters, it is recommended that the indoor unit be located higher than the outdoor unit.)
Pipe length: no more than 20M.
Bends: no more than 3 places.
5.1.2 Outdoor Unit
5.1.2.1 Before installing the outdoor unit, you should:
a). Select a place where no direct sunlight or other heat-radioactivity may reach. A sunshade is needed if
it is unavoidable.
b). Select a place that is easy to connect indoor unit's pipe and electric wires.
c). Avoid a place where combustible gas may leak or stay.
d). Keep it in mind that water may drain out of the outdoor unit while in "Heat" mode.
Caution:
Installation in the following places may cause trouble. If it is unavoidable to use in such places, please
consult with the dealer.
Содержание MFGA-60ARDN1-QC2
Страница 1: ...SERVICE MANUAL AIRCONDITIONER FLOOR STANDING TYPE Model MFGA 60ARDN1 QC2 ...
Страница 6: ...3 2 Dimension 2 1 Indoor Unit Dimension Mode W mm D mm H mm MFGA 60ARDN1 QC2 610 390 1925 ...
Страница 7: ...4 2 2 Outdoor Unit MODEL A B C D E F H MOU 60HDN1 R 940 600 376 400 340 360 1245 ...
Страница 9: ...6 4 Wiring diagram MFGA 60ARDN1 QC2 Indoor Unit Outdoor Unit ...