Midea R410A T3 Top-discharge Split Type Series 50Hz MCAC-UTSM-201501
107
Timer lamp flashing at 5Hz, Operation lamp flashing at 5Hz
Defrosting lamp flashing at 5Hz
For these series products, if the condenser temperature sensor malfunction is displayed, it is
enough to check whether wiring has problem. If the wiring is correct, the PCB should be
replaced.
Operation lamp and timer lamp flashing at 5Hz
11.5 Floor-standing type indoor unit malfunction and protection codes
Display content
Fault or protection meaning
E0
EEprom error
E1
T1, room temperature sensor, fault of open circuit, short circuit.
E2
T2, pipe temperature sensor, fault of open circuit, short circuit.
P1
Under cooling mode, T2 is on low temperature protection.
P2
Under heating mode, T2 is on high temperature protection.
Содержание MFA-76C(H)RN1
Страница 17: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 16 Pipe side view 4 Service Space Top view...
Страница 21: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 20 MTA 120CRN1 MTA 150CRN1...
Страница 35: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 34 MTA 120C H RN1 MTA 150CRN1...
Страница 36: ...Midea R410A T3 Top discharge Split Type Series 50Hz MCAC UTSM 201501 35 MHB 76C H RN1 MHB 96C H RN1...
Страница 44: ...Midea R410A T3 Top discharge Split Type Series 50Hz MCAC UTSM 201501 43 3 Dimensions 4 Service Space...
Страница 46: ...Midea R410A T3 Top discharge Split Type Series 50Hz MCAC UTSM 201501 45 6 Wiring Diagrams MFA 76HRN1 MFA 96HRN1...
Страница 47: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 46 MFA 76CRN1 MFA 96CRN1 MFAT 120CRN1...
Страница 109: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 108 E0 E1 E2 P1...
Страница 113: ...MCAC UTSM 201501 Midea R410A T3 Top discharge Split Type Series 50Hz 112 System low pressure protection...
Страница 154: ...Midea R410A T3 Top discharge Split Type Series 50Hz MCAC UTSM 201501 153 3 The wire connection...