57
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red
(-)Black
∞
(Several MΩ)
(+)Red
(-)Black
∞
(Several MΩ)
P
N
U
N
U
V
V
W
W
(+)Red
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
RPG13B
RPG15A
RPG20B
RPG28H
RPG45B
Black -
Red
530Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
75Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
381Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
183.6Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
112Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
118.5Ω±8%
(20
℃/68℉
)
(Brand: Broad
Ocean)
White -
Black
315Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
150Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
267Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
206Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
82Ω±8%
(20
℃/68℉
)
(Brand:
Welling)
78.5Ω±8%
(20
℃/68℉
)
(Brand: Broad
Ocean)
Содержание MCHS-09NIH1
Страница 11: ...9 6 Wiring Diagram 6 1 Indoor Unit MEHS 09NiH1 MEHS 12NiH1 MEHS 09NiH2 MEHS 12NiH2 MEHS 18NiH2...
Страница 12: ...10 MEHS 22NiH2...
Страница 13: ...11 6 2 Outdoor Unit MCHS 09NiH1 MCHS 12NiH1...
Страница 14: ...12 MCHS 09NiH2 MCHS 12NiH2...
Страница 15: ...13 MCHS 18NiH2 MCHS 22NiH2...
Страница 16: ...14 For MCHS 12NiH2 For MCHS 09NiH1 MCHS 12NiH1...
Страница 17: ...15 For MCHS 09NiH2 For MCHS 18NiH2...
Страница 18: ...16 For MCHS 22NiH2...
Страница 50: ...48 P W P N...