9.4 Operation Modes and Functions
9.4.1 Fan mode
(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled,
and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling
mode.
(5) Auto fan:
27.5
27
High
Low
25
Medium
25.5
9.4.2 Cooling Mode
9.4.2.1 Compressor running rules
The maximum operation frequency of
compressor after starting submits to following
rule.
45
43
40
38
31.5
29.5
22
20
Fmax=F4
Fmax=F7
Fmax=F8
Fmax=F6
Fmax=F3
Fmax: The maximum operation frequency of
compressor.
F1~F8: The detailed value of the compressor
operation frequency.
If users switch on AC by remote controller, the
compressor will run at the Fmax frequency for 7
minutes according to the outdoor ambient temp.
During the 7 minutes, the frequency limitation is
active. 7 minutes later, the compressor running
frequency will be controlled as below:
3.5
3.0
2.5
2.0
1.5
1.0
0.5
-0.5
-1.0
A
B
C
D
E
F
G
H
While the zones of A,B,C... are corresponding
to different compressor running frequency.
Note:
When T1-Ts keeps in the same temp. zone for
3 minutes, the compressor will run as the below
rules:
A~E: Increase the frequency to the higher level
until to F8.
F: Keep the current frequency.
G: Decrease the frequency to the lower level
until to F1.
H: Run at F1 for 1h.(if T1-Ts<-2
℃
, the
compressor will stop)
Meanwhile, the compressor running frequency
is limited by the current.
Содержание MCHS-09NIH1
Страница 11: ...9 6 Wiring Diagram 6 1 Indoor Unit MEHS 09NiH1 MEHS 12NiH1 MEHS 09NiH2 MEHS 12NiH2 MEHS 18NiH2...
Страница 12: ...10 MEHS 22NiH2...
Страница 13: ...11 6 2 Outdoor Unit MCHS 09NiH1 MCHS 12NiH1...
Страница 14: ...12 MCHS 09NiH2 MCHS 12NiH2...
Страница 15: ...13 MCHS 18NiH2 MCHS 22NiH2...
Страница 16: ...14 For MCHS 12NiH2 For MCHS 09NiH1 MCHS 12NiH1...
Страница 17: ...15 For MCHS 09NiH2 For MCHS 18NiH2...
Страница 18: ...16 For MCHS 22NiH2...
Страница 50: ...48 P W P N...