43
Index 1:
1:Indoor or Outdoor DC Fan Motor(control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor
connector. If the value of the voltage is not in the range showing in below table, the PCB must has
problems and need to be replaced.
DC motor voltage input and output(voltage: 220-240V~)
NO.
Color
Signal
Voltage
1
Red
Vs/Vm
280V~380V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
14-17.5V
5
Yellow
Vsp
0~5.6V
6
Blue
FG
14-17.5V
DC motor voltage input and output(voltage :115V~)
NO.
Color
Signal
Voltage
1
Red
Vs/Vm
140V~190V
2
---
---
---
3
Black
GND
0V
4
White
Vcc
14-17.5V
5
Yellow
Vsp
0~5.6V
6
Blue
FG
14-17.5V
2.
Outdoor DC Fan Motor (control chip is in outdoor PCB)
Power on ,and check if the fan can run normally, if the fan can run normally, the PCB must has
problems and need to be replaced, If the fan can’t run normally, measure the resistance of each two
pins. If the resistance is not equal to each other, the fan motor must have problems and need to be
replaced, otherwise the PCB must has problems and need to be replaced.
3. Indoor AC Fan Motor
Power on and set the unit running in fan mode at high fan speed. After running for 15 seconds,
measure the voltage of pin1 and pin2. If the value of the voltage is less than 100V(208~240V power
supply)or 50V(115V power supply), the PCB must has problems and need to be replaced.
Содержание MCHS-09NIH1
Страница 11: ...9 6 Wiring Diagram 6 1 Indoor Unit MEHS 09NiH1 MEHS 12NiH1 MEHS 09NiH2 MEHS 12NiH2 MEHS 18NiH2...
Страница 12: ...10 MEHS 22NiH2...
Страница 13: ...11 6 2 Outdoor Unit MCHS 09NiH1 MCHS 12NiH1...
Страница 14: ...12 MCHS 09NiH2 MCHS 12NiH2...
Страница 15: ...13 MCHS 18NiH2 MCHS 22NiH2...
Страница 16: ...14 For MCHS 12NiH2 For MCHS 09NiH1 MCHS 12NiH1...
Страница 17: ...15 For MCHS 09NiH2 For MCHS 18NiH2...
Страница 18: ...16 For MCHS 22NiH2...
Страница 50: ...48 P W P N...