CONTENTS

SAFETY PRECAUTIONS

Warning ....................................................................................................................................2
Caution .....................................................................................................................................2

INSTALLATION INSTRUCTIONS

Selecting installation place........................................................................................................3
Accessories ........ .....................................................................................................................4
Indoor unit installation................................................................................................................5
Outdoor unit installation.............................................................................................................7

REFRIGERANT PIPE CONNECTION

Refrigerant pipe connection .....................................................................................................8

Inside you will find many helpful hints on how to install and test the air conditioner properly.

 

   Contact an authorised service technician for repair or maintenance of this unit.
   Contact an authorised installer for installation of this unit.
   The air conditioner is not intended for use by young children or infirmed persons 
   without supervision.
   Young children should be supervised to ensure that they do not play with the air 
   conditioner.
   If the power cord is to be replaced, replacement work shall be performed by 
   authorised personnel only.
   Installation work must be performed in accordance with the national wiring Standards
   by authorised personnel only. 

!

CAUTION

Read This Manual

ELECTRICAL WORK

Electrical work .................. .....................................................................................................9

TEST RUNNING

Test running ...................... .....................................................................................................13

AIR PURGING

Air purging with vacuum pump ..............................................................................................11
Satety and leakage check .....................................................................................................13

Содержание Elite Plus MSE18HRN1

Страница 1: ...please read this manual carefully and keep it for future reference ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference ROOM AIR CO...

Страница 2: ...authorised installer for installation of this unit The air conditioner is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure t...

Страница 3: ...nd this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock f...

Страница 4: ...e connection side right side should have more than 60cm of clearance Do not place animals and plants in the path of the air inlet or outlet Take the air conditioner weight into account and select a pl...

Страница 5: ...should be free from obstructions CAUTION 1 2 3 4 5 6 7 Parts you must purchase The minimum pipe wall thickness of 0 7mm is required 6 35 9 53 12 7 8 2 Self tapping Screw B ST2 9X10 Remote controller I...

Страница 6: ...ponding mounting points on the installation plate Dimensions are in mm unless otherwise stated 1 Determine hole positions according to the diagram detailed in Fig 5 Drill one 1 hole 65mm slanting slig...

Страница 7: ...oor unit from side to side to see that it is securely hooked 3 Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall Get it out after fin...

Страница 8: ...n hose sloped downward to drain out the cond ensed water smoothly CAUTION Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction wh...

Страница 9: ...90 C Roughness Burr Main cause for refrigerant leakage is due to defect in the flaring work Carry out correct flaring work using the following procedure A Cut the pipes and the cable 1 Use the piping...

Страница 10: ...8 1 0 9 53 2940 300kgf cm 3430 350kgf cm Fig 19 Indoor unit tubing Flare nut Pipings Fig 18 Electric safety regulations for the initial Installation 1 If there is serious safety problem about the pow...

Страница 11: ...ft the indoor unit panel up remove the electrical box cover by loosening the screw 4 Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively 5 Wrap th...

Страница 12: ...onnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active phase conductors CAUTION CAUTION CAUTION CAUTION Air and m...

Страница 13: ...Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare nut of the Lo valve on the gas pipe side and check that the air is entering Operation...

Страница 14: ...t connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th piping If bubbles come out the pipes have leakage 2 Leak detector Use the leak detector to...

Страница 15: ...CS406 I1 2200018041...

Отзывы: