SYSTEM REQUIREMENTS

Allow sufficient space for airflow and servicing unit. See Fig. 6 for minimum required distances between the unit and the walls or ceilings.

Piping

IMPORTANT:

 

Both refrigerant lines must be insulated separately.

S

  Minimum refrigerant line length between the indoor and outdoor units is 10 ft. (3 m).

S

  Table 3 lists the pipe sizes for the indoor unit. Refer to the outdoor unit installation instructions for other allowed piping lengths and refrigerant

information.

Table 3—Piping Lengths

9

K

12K

18K

24K

36K

48K

58K

Gas Pipe (size-connection type)

In.

(mm)

3/8

(9.52)

1/2

(12.7)

1/2

(12.7)

5/8

(16)

5/8

(16)

5/8

(16)

3/4

(19)

Liquid Pipe (size-connection type)

In

(mm)

1/4

(6.35)

1/4

(6.35)

1/4

(6.35)

3/8

(9.52)

3/8

(9.52))

3/8

(9.52)

3/8

(9.52)

WIRING

All wires must be sized per NEC (National Electrical Code) or CEC
(Canadian Electrical Code) and local codes. Use Electrical Data table
MCA (minimum circuit amps) and MOCP (maximum over current
protection) to correctly size the wires and the disconnect fuse or
breakers respectively.

Sizes 09−24 Recommended Connection Method for
Power and Communication Wiring

Power and Communication Wiring:

The main power is supplied to the outdoor unit. The field supplied 14/3
power/communication wiring from the outdoor unit to the indoor unit
consists of four (4) wires and provides the power for the indoor unit.
Two wires are high voltage AC power, one is communication wiring
and the other is a ground wire.

To minimize communication interference: If installed in a high
Electromagnetic field (EMF) area and communication issues exist, a
14/2 stranded shielded wire can be used to replace L2 and (S) between
outdoor unit and indoor unit − landing the shield onto ground in the
outdoor unit only.

Sizes 36−58 Recommended Connection Method for
Power and Communication Wiring

Power and Communication Wiring:

The main power is supplied to the outdoor unit. The field supplied
power wiring from the outdoor unit to the indoor unit consists of three
(3) wires and provides the power for the indoor unit. Two wires are
high voltage AC power and one is a ground wire. To minimize voltage
drop, the factory recommended wire size is 14/2 stranded with a
ground.

Communication Wiring:

A separate shielded stranded copper conductor only, with a 600 volt
rating and double insulated copper wire, must be used as the
communication wire from the outdoor unit to the indoor unit. Please
use a separate shielded 16GA stranded control wire.

!

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment
damage or improper operation.

Wires should be sized based on NEC and local codes.

CAUTION

CAUTION

!

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage
or improper operation.

Be sure to comply with local codes while running wire from
the indoor unit to the outdoor unit.

Every wire must be connected firmly. Loose wiring may cause
the terminal to overheat or result in unit malfunction. A fire
hazard may also exist. Ensure all wiring is tightly connected.

No wire should touch the refrigerant tubing, compressor or
any moving parts.

Disconnecting means must be provided and shall be located
within sight and readily accessible from the air conditioner.

Connecting cable with conduit shall be routed through the
hole in the conduit panel.

CAUTION

Содержание DLFLDA

Страница 1: ...mages are for illustration purposes only Actual models may differ slightly TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS LIST 3 SYSTEM REQUIREMENTS 4 WIRING 4 DIMENSIONS 5 INSTALLATION CLEARANC...

Страница 2: ...ill result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal i...

Страница 3: ...llustration purposes only Notes If the outdoor unit is higher than the indoor unit prevent rain from flowing into the indoor unit along the connection pipe by creating a downward arc in the connection...

Страница 4: ...EMF area and communication issues exist a 14 2 stranded shielded wire can be used to replace L2 and S between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only Sizes...

Страница 5: ...2 29 2 14 2 3 3 5 5 3 3 3 3 40 mm 700 200 506 450 137 537 30 152 599 186 50 741 360 84 140 84 84 18 1 18 In 34 65 8 27 26 54 23 62 5 51 27 80 1 97 5 35 30 79 7 48 1 57 36 22 20 3 07 5 83 3 46 4 41 54...

Страница 6: ...6 32801000302 Specifications subject to change without notice DIMENSIONS CONT Airflow Airflow Fig 5 Indoor Unit Sizes 58K...

Страница 7: ...ess Panel 17 7 in 45cm x 17 7 in 45cm 7 8 in 20cm 11 81 in 30cm 4 in 10cm Bottom Return Blower Motor Service Clearance Filter Service Clearance Blower Motor Service Clearance PCB Board Service Clearan...

Страница 8: ...ling grid is supported separately from the unit The ceiling grid must not be supported by any part of the unit or any associated wiring or piping work CAUTION MOUNTING THE UNIT 1 INSTALLING HANGER BOL...

Страница 9: ...he condensate piping should be as close to the unit as possible see Fig 17 S Condensate piping should slope downward in the direction of condensate flow with a minimum gradient of 1 100 S When multipl...

Страница 10: ...with clamps on both ends c Connect the drainpipe to the connector D see Fig 20 d Plug the power cable of the external pump to CN13 PUMP pin and plug the water level sensor cable to the CN5 WATER to en...

Страница 11: ...T PUMP AND DRAINAGE TEST Follow these steps to perform the test 1 Remove the test cover by rotating it counter clockwise as shown in Fig 27 2 Using a piece of tubing or pipe fill the condensate lift p...

Страница 12: ...lection either SP or AF NOTE T1 T2 T26 T3 T4 are sub menus for thermistors Do not select for setting external static pressure Fig 30 Wired Controller Menu Selection 1 If setting the external static pr...

Страница 13: ...40 Pa 24 42 72 98 0 100 24 In WG 0 10 0 216 0 336 0 528 0 0 64 Pa 25 54 84 132 0 160 36 In WG 0 168 0 312 0 48 0 62 0 0 64 Pa 42 78 120 155 0 160 48 In WG 0 18 0 404 0 616 0 64 0 0 64 Pa 45 101 154 1...

Страница 14: ...14 32801000302 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 32 Fan Performance 40MBDQ09...

Страница 15: ...32801000302 15 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 33 Fan Performance 40MBDQ12...

Страница 16: ...16 32801000302 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 34 Fan Performance 40MBDQ18...

Страница 17: ...32801000302 17 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 35 Fan Performance 40MBDQ24...

Страница 18: ...18 32801000302 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 36 Fan Performance 40MBDQ36...

Страница 19: ...32801000302 19 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 37 Fan Performance 40MBDQ48...

Страница 20: ...20 32801000302 Specifications subject to change without notice FAN PERFORMANCES AT VARYING STATIC PRESSURES CONT Fig 38 Fan Performance 40MBDQ58...

Страница 21: ...5 0 56 420 48 3 2 0 75 560 58 3 65 0 952 1000 LEGEND FLA Full Load Amps CONNECTION DIAGRAMS Fig 39 Connection Diagrams sizes 09 to 24 Fig 40 Connection Diagrams sizes 36 and 58 Fig 41 Control and Powe...

Страница 22: ...Table 9 for the flare nut spaces Table 9 Flare Nut Spacing OUTER DIAM mm A mm Max Min 1 4 6 35 0 05 1 3 0 03 0 7 3 8 9 52 0 06 1 6 0 04 1 0 1 2 12 7 0 07 1 8 0 04 1 0 5 8 15 88 0 09 2 2 0 08 2 0 Bar C...

Страница 23: ...a wireless remote controller is used relocate the IR receiver within line of sight of remote location using the 6 ft cable included The factory location of the IR receiver is inside the control box s...

Страница 24: ...Open front panel of the indoor unit 4 Push the manual switch once to energize the unit The set conditions of manual operation are as follows Preset set point 76_F 24_C Fan speed AUTO Discharge air dir...

Страница 25: ...F6 Compressor low pressure protection H 4 times X E3 Indoor fan speed has been out of control H 5 times X E4 Indoor room temperature sensor T1 open circuit or short circuit H 6 times X E5 Evaporator...

Страница 26: ...26 32801000302 Specifications subject to change without notice Copyright 2018 International Comfort Products CMNA 1025 Cobb Place Blvd NW Kennesaw GA 30152...

Отзывы: