Fit the adaptor 3/4" Female BSP x 3/4" Male BSP in the flow inlet connection of the sanitary
hot water tank.
Fit the connection pipe 3/4 " Male BSP x3/4" Male BSP and sealing in the flow inlet connection
of the sanitary hot water tank.
Fit the adaptor 3/4" Male BSP x3/4" Male BSP in the heat exchanger outlet connection of the
sanitary hot water tank.
Fit the solar kit and sealing (x2) on the heat exchanger in let connection and heat exchanger
outlet connection of the sanitary hot water tank. Torque 5 N.m.
Fit the adaptors 3/4" Male BSP x 3/4" Male BSP (x4) to the field piping:
a) Inlet connection from indoor unit
b) Return connection to indoor unit
c) Inlet connection from solar pump station
d) Return connection to solar pump station
Fit the solar kit and sealing (x4) to the field piping .Torque 5N.m.
Mount the left side of the EPP casing onto the solar kit.
Mount the EPP lid onto the right side of the EPP casing.
Mount the right side of the EPP casing onto the solar kit. Take case, that the pump cable is
routed via the holes in the Bottom of the EPP casing.
CAUTION:
Ensure that the pump cable cannot come into contact with piping below the pump when cable
is routed out.
Use the screws and washers (x2) to fix the EPP casing. Screw until tight position.
WARNING
Do not switch inlet and outlet connections.
To install adequate connections between the indoor unit and the solar kit, it is important that
the 2-way valve is fitted correctly.
CAUTION:
Ensure that the water piping connected to the solar kit coming from the solar panel and the
indoor unit are sufficiently supported and do not cause any stress on the solar kit
Charging water
Charge the water on the indoor unit and the tank .Charge the solar panel circuit with a glycol
solution.
CAUTION:
Observe the instructions as given by your solar panel supplier. Make sure to use non-toxic glycol.
Содержание CSD80GN1
Страница 27: ...1 4 Dimensions of the outdoor unit 1 5 Installation space 1 Single unit installation...
Страница 28: ...2 Parallel connect the two units or above 3 Parallel connect the front with rear sides...
Страница 50: ......
Страница 56: ...The connection is described in the following figure The wiring terminal diagram as following figure...
Страница 59: ......
Страница 60: ......
Страница 70: ...M thermal technical manual part 3 3 4 Field setting table...