Requirement
SMK-120/CSD80GN1
SMK-140/CSD80GN1
Maximum allowable refrigerant piping length between outdoor unit and
indoor unit.
50m
Maximum allowable height distance between outdoor
unit and indoor unit when outdoor unit is top.
15m
Maximum allowable height distance between outdoor
unit and indoor unit when outdoor unit is bottom
10m
Maximum allowable distance between the 2-way valve SV1 and the indoor
unit (only for installations with sanitary hot water tank).
3m
Maximum allowable distance between the sanitary hot water tank and the
indoor unit (only for installations with sanitary hot water tank). The
thermistor cable supplied with the indoor unit is 15 min length.
10m
Maximum allowable be distance between the T1B and the indoor unit .The
temperature sensor cable of T1B supplied with the indoor unit is 10m in
length.
8m
The equipment is not intended for use in a potentially explosive atmosphere.
2.3
Dimensions of the hydraulic indoor units
Unit of measurement: mm
Dimensions of the wall bracket:
Dimensions of the unit