background image

Special feature

Air quality is the key to comfort, this air
conditioner is equipped with Ionizer or
Plasma Dust Collector(Depending on models).
Ionizer can generate abundant anions to fill
the room with refreshing and nature air. Your
whole family will enjoy a natural, pure and
healthy air everyday. The Plasma Dust Collector
can generate an ionization zone. The air is
converted to plasma as it passes the high
voltage ion generator. 95% of the dust, smoke,
and pollen particles are attracted to the
electrostatic filter.

CLEAN AIR function(optional)

Function used after the Shut Down
of cooling operation to clean the
Evaporator and keep it as fresh for
the next operation.
This function is easy to be operated
as it is accessed through the
Remote Controller.

This function is only available
under COOL(AUTO COOL,
FORCED COOL)and DRY mode.
Before select the function, it is
recommended to run the air condi-
tioner under Cooling operation for
about half an hour.
Once the Self Clean function is
activated, all TIMER setting will be
cancelled.
During Self Clean operation, when
press the SELF CLEAN button on the
remote controller again will stop the
operation and turn off the unit.

Note:

SELF CLEAN function(optional)

Follow Me function

To activate the Follow Me feature, point the
remote control towards the unit and press the
Follow Me button. T

If the unit does not receive the

Follow Me signal during any 7 minute interval,
the unit will beep to indicate the Follow Me
mode has ended.

he remote display is actual

temperature at its location. The remote control
will send this signal to the air conditioner every
3 minutes interval until press the Follow Me
button again.

The remote control serves as a remote
thermostat allowing for the precise
temperature control at its location.

OPERATING INSTRUCTIONS

6

CLEAN AIR display

(optional)

Displayed when CLEAN AIR
feature is activated.

TIMER display

Displayed

during Timer operation.

DIGITAL DISPLAY

.

Displays the current setting temperature
and malfunction code when the air
conditioner is in operation. When SELF
CLEAN feature is activated, it displays

,,

, ,

Auto-Restart function

When the power is off and then on,
the unit automatically restores the
previous function setting.

AUTO operation display

Displayed

during Auto operation.

When turns off the unit on COOL, DRY,

AUTO (Cool) mode, the air conditioner

will continue operating for 7 minutes
at soft fan speed. This will help to dry
up the water (sweating) inside the
evaporator, and prevent bacterial from
multiplying, supply clean and fresh air.
This function is a factory default setting.
If you want to cancel it, use the remote
controller to select the FAN mode,
press the ON/OFF button to turn on the
unit, press the ON/OFF button again
to turn off the unit after 5 seconds.

Under DRY & Antibacterial mode, do
not restart the air conditioner until the
unit is completely off.

Dry & Antibacterial Function(optional)

Содержание CS494-U

Страница 1: ...at deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first y...

Страница 2: ...to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only CAUTI...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...ond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off t...

Страница 6: ...oor unit 6 5 7 1 2 3 4 8 10 9 12 Air outlet Air inlet Air inlet rear Air inlet side Air outlet 14 15 13 11 Display window Signal receptor DEFROST operation display Displayed when the air conditioner s...

Страница 7: ...unit does not receive the Follow Me signal during any 7 minute interval the unit will beep to indicate the Follow Me mode has ended he remote display is actual temperature at its location The remote c...

Страница 8: ...HIGH fan mode 3 Optimum performance will be achieved within these operating temperature Suggestion For the unit adopts an Electric Heater when the outside ambient temperature is below 0 C we strongly...

Страница 9: ...he horizontal air flow direction left right The DIRECTION SWING button will be disabled when the air conditioner is not in operation including when the TIMER is set Do not operate the air conditioner...

Страница 10: ...automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C the compressor stops operation and restarts until the room temperature is above 12 C O...

Страница 11: ...before start up This operation must be performed by qualified personnel only Cleaning the Grille Case and Remote Controller Thinner A cloth soaked in warm water may be used on the indoor unit if it is...

Страница 12: ...and replace it every 4 5 months Clean it with vacuum cleaner then dry it in cool place 5 Install the air freshening filter back into position 6 Insert the upper portion of air filter back into the un...

Страница 13: ...windows closed The remote controller does not work Check the following 1 Important It only works within a range of 8m from the indoor unit 2 Are the batteries still OK Replace if necessary 3 Have the...

Страница 14: ...ntraction and expansion of the front panel in response to temperature differences The clicking noise may be heard caused by fan or the compressor when switching on or off You may hear moving water Thi...

Страница 15: ...CS494 U 202000192029...

Отзывы: