background image

9

OPERATING INSTRUCTIONS

AUTO operation

SLEEP operation

DRYING operation

When you set the air conditioner in AUTO mode,
it will automatically select cooling, heating(cooling
/heating models only), or fan only operation
depending on what temperature you have selected
and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set
by you.
If the AUTO mode is uncomfortable, you can
select desired conditions manually.

When you push SLEEP button on remote
controller during cooling, heating(cooling only type
without), or AUTO operation , the air conditioner
will automatically increase (cooling) or decrease
(heating) 1

per hour for the first two hours, then

hold steady for the next 5 hours, after that the unit
will stop operation. The fan speed will be auto-
matically controlled. This feature can maintain the
most comfortable temperature and save more
energy for you.

The fan speed will be automatically controlled
under dry operation.
During the dry operation, if the room temperature
is lower than 10 C, the compressor stops operation
and restarts until the room temperature is above
12 C.

O

O

To achieve optimal performance, please note the
following:

Adjust the air flow direction correctly so that it is
not directed on people.
Adjust the temperature to achieve the highest
comfort level. Do not adjust the unit to excessive
temperature levels.
Close doors and windows on COOL or HEAT
modes, or performance may be reduced.
Use TIMER ON button on the remote controller to
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as
the efficiency of the air conditioner may be reduced

and the air conditioner may stop running.

Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.

1 hour

1 hour

Set
Temperature

Cooling

1

1

Heating

SLEEP operation

How the air conditioner works

Optimal operation

1

1

1 hour

1 hour

Set
Temperature

SLEEP operation

7 hours timer off

7 hours timer off

Содержание CS494-U

Страница 1: ...at deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first y...

Страница 2: ...to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only CAUTI...

Страница 3: ...east free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least...

Страница 4: ...ay cause fire and electric shock It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electri...

Страница 5: ...ond itioner to preserve preci sion devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off t...

Страница 6: ...oor unit 6 5 7 1 2 3 4 8 10 9 12 Air outlet Air inlet Air inlet rear Air inlet side Air outlet 14 15 13 11 Display window Signal receptor DEFROST operation display Displayed when the air conditioner s...

Страница 7: ...unit does not receive the Follow Me signal during any 7 minute interval the unit will beep to indicate the Follow Me mode has ended he remote display is actual temperature at its location The remote c...

Страница 8: ...HIGH fan mode 3 Optimum performance will be achieved within these operating temperature Suggestion For the unit adopts an Electric Heater when the outside ambient temperature is below 0 C we strongly...

Страница 9: ...he horizontal air flow direction left right The DIRECTION SWING button will be disabled when the air conditioner is not in operation including when the TIMER is set Do not operate the air conditioner...

Страница 10: ...automatically controlled under dry operation During the dry operation if the room temperature is lower than 10 C the compressor stops operation and restarts until the room temperature is above 12 C O...

Страница 11: ...before start up This operation must be performed by qualified personnel only Cleaning the Grille Case and Remote Controller Thinner A cloth soaked in warm water may be used on the indoor unit if it is...

Страница 12: ...and replace it every 4 5 months Clean it with vacuum cleaner then dry it in cool place 5 Install the air freshening filter back into position 6 Insert the upper portion of air filter back into the un...

Страница 13: ...windows closed The remote controller does not work Check the following 1 Important It only works within a range of 8m from the indoor unit 2 Are the batteries still OK Replace if necessary 3 Have the...

Страница 14: ...ntraction and expansion of the front panel in response to temperature differences The clicking noise may be heard caused by fan or the compressor when switching on or off You may hear moving water Thi...

Страница 15: ...CS494 U 202000192029...