5
General Details
a
CAUTION DANGER
– When connecting refrigerant piping,keep substances or gases other than the specified refrigerant from entering
the unit. The presence of other gases or substances can reduce unit performance and cause an abnormal
increase in pressure in the refrigeration cycle. This can lead to explosion hazards and resulting injuries.
– Install the unit on a stable stand that can support its weight. If the chosen stand cannot support the weight of
the unit, or if the installation is not performed correctly, the unit may fall and cause injury and serious damage.
– Do not pierce or ignite the device.
– The appliance must be placed in a well-ventilated room whose dimensions correspond to those specified
for operation.
– The product must be installed with earthing in accordance with the law to avoid the risk of electrocution.
– Do not install the unit in a location that may be exposed to combustible gas leakage. Any accumulation of
combustible gas around the unit may cause a fire hazard.
– Do not operate the air conditioner in a very humid room, for example in a bathroom or laundry room.
Excessive exposure to water can cause electrical components to short-circuit.
d
IT IS PROHIBITED TO
– Make changes and/or repair attempts to the product. Any repairs must be carried out by a qualified
technician.
– Touch the device with wet, damp and/or barefoot body parts. If you notice current leakage that can be
detected on contact with metal parts of the appliance, disconnect the switch, unplug it from the power
supply socket and contact an authorised dealer.
– Use of the appliance by children and persons with reduced capacity or lack of experience and specific
knowledge unless they are assisted by qualified personnel responsible for their safety.
– Disperse in the environment and leave within the reach of children the packaging material as it may be
a potential source of danger. It must therefore be disposed of in accordance with current legislation.
– Change the length of the power cable or use extension cables to power the unit.
– Use the same electrical outlet for other equipment. Incorrect or insufficient power supply may cause fire or
electric shock hazard.
m
NOTES ON FLUORINATED GASES
– This air conditioner contains fluorinated gas. For specific information on gas types and quantities, please
refer to the plate found on the unit. It is always necessary to comply with national regulations regarding the
use of gases.
– Installation, service, maintenance and repair of the unit must be performed by a qualified technician.
– The uninstallation and recycling of the product must be carried out by qualified technical personnel.
– If a leak detection device is installed in the system, it is necessary to check that there are no leaks at least every
12 months. When checking the unit for leaks, it is recommended to keep a detailed record of all inspections.
– Pay attention to the fact that refrigerant R32 is odourless.
FLAMMABLE MATERIAL
The refrigerant used inside this unit is flammable. A coolant leak that is exposed to an external ignition source
can create fire risks
Содержание CLIVET SINGLESplit STELVIO 27M
Страница 30: ...30 Allegati 8 ALLEGATI 8 1 Schemi elettrici unit esterna 27M 35M SERIE GRANDEZZA MH2 Y 27M 35M...
Страница 31: ...31 Allegati...
Страница 33: ...OUTDOOR UNIT SINGLESplit STELVIO MH2 Y series from 27M to 35M MANUAL FOR INSTALLATION USE AND MAINTENANCE...
Страница 62: ...30 Attachments 8 ATTACHMENTS 8 1 Outdoor Unit Wiring Diagrams 27M 35M SERIES SIZE MH2 Y 27M 35M...
Страница 63: ...31 Attachments...
Страница 65: ...UNIT EXTERNE MONOSplit STELVIO S rie MH2 Y de 27M 35M MANUEL POUR L INSTALLATION L UTILISATION ET L ENTRETIEN...
Страница 94: ...30 Pi ces jointes 8 PI CES JOINTES 8 1 Sch mas lectriques de l unit externe 27M 35M S RIE TAILLE MH2 Y 27M 35M...
Страница 95: ...31 Pi ces jointes...
Страница 97: ...D AUSSENEINHEIT MONOSplit STELVIO Baureihe MH2 Y von 27M bis 35M HANDBUCH F R INSTALLATION GEBRAUCH UND WARTUNG...
Страница 126: ...30 Anlagen 8 ANLAGEN 8 1 Schaltpl ne f r Au eneinheit 27M 35M BAUREIHE GR SSE MH2 Y 27M 35M...
Страница 127: ...31 Anlagen...