Service Manual
, 2016-12
27
/
51
1
After the removal of cover plate of upper air duct
in freezing chamber. Pull the motor fan of upper
air duct in freezing chamber outward to make the
fan blade separate from the motor.
2
)
Remove by cross screwdriver the two fixing screws
anticlockwise. Complete disassembly of the motor
8.6Evaporator and temperature sensing system
Evaporator in freezing chamber
Evaporator in freezing chamber
Remove the air duct components in freezing chamber.
Disconnect all connectors.
Remove the welding on inlet and outlet tubes.
Remove two screws which are used to fix the evaporator
and remove the evaporator.
Components on the evaporator