Service Manual
, 2016-12
40
/
51
10.5
REF.fan motor circuit(None)
10.6
Condenser fan motor circuit(None)
10.7
Damper motor circuit
The damper is controlled by stepping motor, the output is square wave by control of speical control chip, when
the refrigerator comparment request cooling , the motor switch on, otherwise, the motor switch off.
10.8
Sensor resistance
(R/T)
Tx(
℃
)
R
K
Ω
Tx(
℃
)
R
K
Ω
Tx(
℃
)
R
K
Ω
Tx(
℃
)
R
K
Ω
Tx(
℃
)
R
K
Ω
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486
-27
28.29
-12
12.16
3
5.587
18
2.737
33
1.426
-26
26.68
-11
11.52
4
5.315
19
2.616
34
1.368
-25
25.17
-10
10.92
5
5.06
20
2.501
35
1.312
-24
23.76
-9
10.35
6
4.818
21
2.391
36
1.259
-23
22.43
-8
9.82
7
4.589
22
2.287
37
1.209
-22
21.18
-7
9.316
8
4.372
23
2.188
38
1.161
-21
20.01
-6
8.841
9
4.167
24
2.094
39
1.115
-20
18.9
-5
8.392
10
3.972
25
2.005
40
1.071
-19
17.87
-4
7.968
11
3.788
26
1.919
41
1.029
-18
16.9
-3
7.568
12
3.613
27
1.838
42
0.9885
-17
15.98
-2
7.19
13
3.447
28
1.761
43
0.9506
-16
15.12
-1
6.833
14
3.29
29
1.687
44
0.914
Содержание CE-BCD505WE-ST
Страница 1: ...1 54 SBS SERIES Service Manual 2016...
Страница 6: ...Service Manual 2016 12 5 51 1 Safety Warning Code 1 1Warning for operation safety...
Страница 7: ...Service Manual 2016 12 6 51...
Страница 8: ...Service Manual 2016 12 7 51...
Страница 9: ...Service Manual 2016 12 8 51 1 2Safety instruction for refrigerant...
Страница 42: ...Service Manual 2016 12 41 51 11 Troubleshooting Method 11 1No cooling Air cooling Electronic...
Страница 43: ...Service Manual 2016 12 42 51 11 2No working of compressor 11 3Inside frosting no defrosting...
Страница 44: ...Service Manual 2016 12 43 51 11 4 Inside frosting no defrosting Maintenance guidelines...
Страница 45: ...Service Manual 2016 12 44 51 11 5Light is not on 11 6Air duct not operated electronically...
Страница 46: ...Service Manual 2016 12 45 51 11 7Fan failure 11 8Defective defrost circuit...
Страница 49: ......