Aqua Tempo Super II
201902
33
P
art
2
- Engineering
Da
ta
Table 2-5.3: MC-SU90-RN1L heating capacity
Ambient
temp.
(°C)
Chilled water outlet temperature (
°
C)
30.00
35.00
40.00
45.00
50.00
55.00
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
-20.00
55.21
23.46
46.32
23.36
37.63
22.86
-
-
-
-
-
-
-15.00
62.23
23.93
51.23
23.29
42.32
24.89
35.87
25.17
-
-
-
-
-7.00
70.86
22.24
62.32
23.97
54.12
27.06
43.84
26.16
36.23
24.15
-
-
2.00
86.74
26.27
82.46
29.45
78.56
34.16
71.90
33.50
54.26
30.15
35.41
23.66
7.00
98.22
29.36
95.11
30.19
92.65
30.88
90.07
33.63
85.32
31.6
68.16
26.64
15.00
90.32
25.81
86.23
26.1
83.36
26.46
78.66
29.13
74.53
27.61
48.36
21.98
20.00
85.63
23.79
82.45
24.25
78.56
23.81
74.36
27.54
72.32
26.78
21.15
11.47
25.00
82.42
22.04
78.63
22.46
74.56
23.30
72.21
22.56
69.97
25.34
27.86
11.74
30.00
78.22
20.52
74.23
20.62
68.44
20.61
64.12
22.89
56.23
20.07
24.26
11.84
Abbreviations:
TC: Total capacity (kW)
PI: Power input (kW)
Notes:
1.
Performance specifications measured with water pump operating at rated water flow rate.
Содержание Aqua Tempo Super II Series
Страница 1: ......
Страница 13: ...Aqua Tempo Super II 14 201902 Midea Aqua Tempo Super II Engineering Data Book...
Страница 99: ......