background image

4

}

8

7

6

5

4

L2

L1

9

10

11

12

13

14

15

16

Connect

To

Connect

To

[13]

[14]

[15]

[16]

[1]

[2]

Remove

From

Remove

From

[5]

[6]

[L2]

[L1]

[G]

500

Not used on
certain model
gas and electric
ovens.

NO CONNECT

FIGURE 2 - BACK SIDE OF TEMPERATURE CONTROLLER

}

8

7

6

5

4

L2

L1

9

10

11

12

13

14

15

16

Connect

To

Connect

To

[13]

[14]

[15]

[16]

[1]

[2]

Remove

From

Remove

From

[5]

[6]

[L2]

[L1]

[G]

500

Not used on
certain model
gas and electric
ovens.

NO CONNECT

NO CONNECT

}
}

P.I.D. Output used only
when the temperature controller
is programmed for a model

360EWB

with the modulating 

gas control system.

}

Standard On/Off output
terminals for all models
except 360EWB.

Figure 2 - Analog to Digital Terminal

Cross Reference

TABLE 1 - TERMINAL CROSS REFERENCE

TERMINAL ON
OLD MODULE:

TERMINAL ON
NEW MODULE:

DESCRIPTION OF TERMINAL

500

TABLE 1 - TERMINAL CROSS REFERENCE

TERMINAL ON
OLD MODULE:

TERMINAL ON
NEW MODULE:

1

+ T/C

8

2

- T/C

7

5

Input to Temperature

5

Control Relay

6

Output to High Flame

4

Solenoid or Heater
Contactors

L2

Neutral

L2

L1

Power

L1

G

Ground

13

 

Input to Cool-Down

 9

Relay

14

Output from Cool-Down

10

Relay

15

Input to High-Limit

11

Relay

16

Output from High-Limit

12

Relay

N/A

Modulating Valve Output

15

Terminals (360EWB ONLY)

16

DESCRIPTION OF TERMINAL

500

Figure 3 - Modulating Control Circuit

Move wires
at terminals 
4 & 5 to 15 & 16
for the model
360EWB only

NO CONNECTION

NO CONNECTION

Table 1 - Terminal Cross Reference

4

5

6

7

8

9

10

11

12

13

14

15

16

G

L1

L2

6

5

4

3

1

2

24V AC
  Input

4-20 milliamps

Temperature Controller
 

PN 36056

Amplifier Board
 

Modulating Valve
 

0-24 VDC

     4-20 Milliamp Connection
Output From Terminals 15 &16

+

-

+

-

(Kit PN 36939)

Purple

Purple/White

Содержание 36939

Страница 1: ...0 FAX 847 741 4406 Middleby Corporation 24 Hour Service Hotline 1 800 238 8444 1997 Middleby Marshall Inc Part 36622 P 9 97 Rev B Kit Contents Qty Part Number Description 1 36056 On Off PID Digital Te...

Страница 2: ...h g h h g h 6Xf W h g h K e 7 h g h M g M I 6K h g h Yh H N W26X gW2 e Xh h e hf W X gW2 6Xe h g h J H hJ 5 W g L 7 1 g7 e h h e hf 7 1 Lg7 1e h g h 75he7 HfW he75gJ H N1 f J Le Yh h e hf 1g e h g h...

Страница 3: ...sociated wiring from the terminals located on the rear of the Temperature Controller Disconnect and retain any jumper wires Be sure to tag the ends of controller wires with the number terminal they co...

Страница 4: ...d Table 1 to identify the electrical connections Also refer to step 4 if installing the latest Temperature Controller for the Modulating Configuration used in a 360EWB oven 2 If you are replacing an A...

Страница 5: ...D MODULE TERMINAL ON NEW MODULE DESCRIPTION OF TERMINAL 500 TABLE 1 TERMINAL CROSS REFERENCE TERMINAL ON OLD MODULE TERMINAL ON NEW MODULE 1 T C 8 2 T C 7 5 Input to Temperature 5 Control Relay 6 Outp...

Страница 6: ...controller refer to table 2 for specific wiring instructions for all wires and any jumpers to be reinstalled PS360 6 00 PS200 13 38 cable Current Thermocouple Flange Obsolete Thermocouple Clip Figure...

Страница 7: ...igure 6 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1Ph 3W Figure 5 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1 Ph 2W Export Only Figure 5 PS310 314 360 360WB Gas Oven 190 380V 50 60Hz 1Ph 2W Ex...

Страница 8: ...Hg h f g f 0Y N h 7 Hg N 7 Hhf f V X hf I X V 5 h 3 Lh 7 he hf f f f g f H J Ke O h 3 LfJ e hfO2 Lh3 Y W M hfJ 5g Hh I 1f hO2 J J g N g h f g f h h Lhf J hf gV X V X N H h N X gJ 5 he 3 5 7 L g L N 1...

Страница 9: ...eN H f h g V Khf N Yhe V Y 7 5 W M I X e W M I X eW MeI Xe fI XfW MeI Xe3 L e 1 eJ 5 X f XfW2 5 L h N Y he W 5 g N J h W H e h Lg J 5 f e g h hV 6Khf H he V Y H W Y eV4 e 7 HfN 1 e7 H e N 1e f V X e7...

Страница 10: ...programming the controller for either the standard ON OFF mode or the PID 360EWB models mode for the modulating gas control system or On O F P d LOCK KEY DISPLAY KEY OnOF standard on off temperature...

Страница 11: ...erature condition when lit On above 650 F 343 C TEMPERATURE KEY Use to view actual oven temperature Digital Temperature Controller P N 36056 Operators Instructions HEAT ON SET PT ACTUAL TEMP SP LOCK O...

Страница 12: ...resistance reading should be in the 9 20 Ohm range Remove replace an open thermocouple 3 If the thermocouple checks good call MCSG for assistance Reverse polarity of the thermocouple leads 1 Check th...

Отзывы: