background image

Digital Temperature Controller

PN 36056

Service instructions

Push the lock key and the service key together to reach SP LOK,
then use the service key to step through the other functions listed
below.

Use the arrow keys to change the function settings.

Factory settings are as shown below.

This function will record the
highest ambient temperature of
the temperature controller;
68ºF/20ºC is the original
reading.

F = degrees Fahrenheit
C = degrees Celsius

SET = set point display
ACT = actual temperature
 display.

LOCK

KEY

SERVICE

KEY

+

NO = set point
         unlocked
YES = set point
          locked

no 

d Eg F

5 E 

68

Push the lock key and the display key to  
enable the programming function of  the  
“OnOF or “Pid” temperature control  
system. 

This display allows programming the controller for either the  
standard O N / O F F  mode or the PID (360EWB models) mode for  
the modulating gas control system.  

or 

O n O F

P d

LOCK

KEY

DISPLAY

KEY

OnOF = standard on/off temperature cycling system (gas & electric)
  PiD =  modulating temperature proportioning system
             (gas 360 EWB only)

1)

2)

OVER TEMP

SET PT

SP LOCK

SP LOCK

HEAT ON

ACTUAL
TEMP

SET PT

HEAT ON

ACTUAL
TEMP

OVER TEMP

SP LOCK

OVER TEMP

SP LOCK
OVER TEMP

F

SET PT

HEAT ON

ACTUAL
TEMP

b

0

SET PT

HEAT ON

ACTUAL
TEMP

OVER TEMP

SP LOCK

SET PT

HEAT ON

ACTUAL
TEMP

E

y

L

S

Confirms that the Pid
(Modulating) setting
has been locked in if
the Pid setting was
chosen.

If the “On/Of” setting is chosen, the
“LyES” display will be bypassed.

This display is the BIAS (actual
temperature) adjustment scale
which is Factory set at zero.
The Factory must be consulted
for any adjustments to the
BIAS.

Indicator flashing

Indicator not flashing

9

Figure 14 - Service Instructions

Содержание 36939

Страница 1: ...0 FAX 847 741 4406 Middleby Corporation 24 Hour Service Hotline 1 800 238 8444 1997 Middleby Marshall Inc Part 36622 P 9 97 Rev B Kit Contents Qty Part Number Description 1 36056 On Off PID Digital Te...

Страница 2: ...h g h h g h 6Xf W h g h K e 7 h g h M g M I 6K h g h Yh H N W26X gW2 e Xh h e hf W X gW2 6Xe h g h J H hJ 5 W g L 7 1 g7 e h h e hf 7 1 Lg7 1e h g h 75he7 HfW he75gJ H N1 f J Le Yh h e hf 1g e h g h...

Страница 3: ...sociated wiring from the terminals located on the rear of the Temperature Controller Disconnect and retain any jumper wires Be sure to tag the ends of controller wires with the number terminal they co...

Страница 4: ...d Table 1 to identify the electrical connections Also refer to step 4 if installing the latest Temperature Controller for the Modulating Configuration used in a 360EWB oven 2 If you are replacing an A...

Страница 5: ...D MODULE TERMINAL ON NEW MODULE DESCRIPTION OF TERMINAL 500 TABLE 1 TERMINAL CROSS REFERENCE TERMINAL ON OLD MODULE TERMINAL ON NEW MODULE 1 T C 8 2 T C 7 5 Input to Temperature 5 Control Relay 6 Outp...

Страница 6: ...controller refer to table 2 for specific wiring instructions for all wires and any jumpers to be reinstalled PS360 6 00 PS200 13 38 cable Current Thermocouple Flange Obsolete Thermocouple Clip Figure...

Страница 7: ...igure 6 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1Ph 3W Figure 5 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1 Ph 2W Export Only Figure 5 PS310 314 360 360WB Gas Oven 190 380V 50 60Hz 1Ph 2W Ex...

Страница 8: ...Hg h f g f 0Y N h 7 Hg N 7 Hhf f V X hf I X V 5 h 3 Lh 7 he hf f f f g f H J Ke O h 3 LfJ e hfO2 Lh3 Y W M hfJ 5g Hh I 1f hO2 J J g N g h f g f h h Lhf J hf gV X V X N H h N X gJ 5 he 3 5 7 L g L N 1...

Страница 9: ...eN H f h g V Khf N Yhe V Y 7 5 W M I X e W M I X eW MeI Xe fI XfW MeI Xe3 L e 1 eJ 5 X f XfW2 5 L h N Y he W 5 g N J h W H e h Lg J 5 f e g h hV 6Khf H he V Y H W Y eV4 e 7 HfN 1 e7 H e N 1e f V X e7...

Страница 10: ...programming the controller for either the standard ON OFF mode or the PID 360EWB models mode for the modulating gas control system or On O F P d LOCK KEY DISPLAY KEY OnOF standard on off temperature...

Страница 11: ...erature condition when lit On above 650 F 343 C TEMPERATURE KEY Use to view actual oven temperature Digital Temperature Controller P N 36056 Operators Instructions HEAT ON SET PT ACTUAL TEMP SP LOCK O...

Страница 12: ...resistance reading should be in the 9 20 Ohm range Remove replace an open thermocouple 3 If the thermocouple checks good call MCSG for assistance Reverse polarity of the thermocouple leads 1 Check th...

Отзывы: