Diagnostic Error Messages

The controller runs background tests during normal operation. If a problem with the background tests occurs, an error
message is shown (flashing) in the Display.  These are called Diagnostic Error Messages (Table 3).

Display

Corrective Action

rPLC

rSET

OPEn

r TC

Oven temperature has
not reached at least
200˚F(93˚C) within 15
minutes of operation.
Usually a result of the
burner not lighting.

1. Turn Blower Switch OFF for 2
minutes, then Turn Blower Switch
ON.

2. If problem does not clear, call
the Middleby Cooking Systems
Group (MCSG) for assistance.

Caused by an
open circuit in the
thermocouple circuit.

1. Check that the thermocouple is
connected to terminals 7 & 8 of the
temperature controller.

2. If connections are good, then check
the continuity of the thermocouple at
room temperature.  The resistance
reading should be in the 9 - 20 Ohm
range.  Remove & replace an open
thermocouple.

3. If the thermocouple checks good,
call MCSG for assistance.

Reverse polarity of the
thermocouple leads.

1. Check the polarity of the
thermocouple leads; terminal 7 (-)
RED wire & terminal 8 (+) WHITE
wire.

2. If polarity connections are
correct replace thermocouple.

Flashes on the display
alternately with
temperature indicating
that the controller’s
internal diagnostics test
has failed.

1. Turn Blower Switch OFF for 2
minutes, then Turn Blower Switch
ON.

2. Replace the controller if the
problem does not clear after repeating
action 1 above three times.

Table 3 - Diagnostic Error Messages

Oven temperature has
not reached at least
200˚F(93˚C) within 15
minutes of operation;
usually a result of the
burner not lighting.

Middleby Marshall Inc. • 1400 Toastmaster Drive • Elgin, IL 60120 • (847) 741-3300 • FAX (847) 741-4406

Middleby Corporation 24 Hour Service Hotline 1-800-238-8444

©1997 Middleby Marshall Inc.

Part # 36622

Page 11 of 11

P 9/97, Rev. B

Содержание 36939

Страница 1: ...0 FAX 847 741 4406 Middleby Corporation 24 Hour Service Hotline 1 800 238 8444 1997 Middleby Marshall Inc Part 36622 P 9 97 Rev B Kit Contents Qty Part Number Description 1 36056 On Off PID Digital Te...

Страница 2: ...h g h h g h 6Xf W h g h K e 7 h g h M g M I 6K h g h Yh H N W26X gW2 e Xh h e hf W X gW2 6Xe h g h J H hJ 5 W g L 7 1 g7 e h h e hf 7 1 Lg7 1e h g h 75he7 HfW he75gJ H N1 f J Le Yh h e hf 1g e h g h...

Страница 3: ...sociated wiring from the terminals located on the rear of the Temperature Controller Disconnect and retain any jumper wires Be sure to tag the ends of controller wires with the number terminal they co...

Страница 4: ...d Table 1 to identify the electrical connections Also refer to step 4 if installing the latest Temperature Controller for the Modulating Configuration used in a 360EWB oven 2 If you are replacing an A...

Страница 5: ...D MODULE TERMINAL ON NEW MODULE DESCRIPTION OF TERMINAL 500 TABLE 1 TERMINAL CROSS REFERENCE TERMINAL ON OLD MODULE TERMINAL ON NEW MODULE 1 T C 8 2 T C 7 5 Input to Temperature 5 Control Relay 6 Outp...

Страница 6: ...controller refer to table 2 for specific wiring instructions for all wires and any jumpers to be reinstalled PS360 6 00 PS200 13 38 cable Current Thermocouple Flange Obsolete Thermocouple Clip Figure...

Страница 7: ...igure 6 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1Ph 3W Figure 5 PS310 314 360 360WB Gas Oven 208 240V 50 60Hz 1 Ph 2W Export Only Figure 5 PS310 314 360 360WB Gas Oven 190 380V 50 60Hz 1Ph 2W Ex...

Страница 8: ...Hg h f g f 0Y N h 7 Hg N 7 Hhf f V X hf I X V 5 h 3 Lh 7 he hf f f f g f H J Ke O h 3 LfJ e hfO2 Lh3 Y W M hfJ 5g Hh I 1f hO2 J J g N g h f g f h h Lhf J hf gV X V X N H h N X gJ 5 he 3 5 7 L g L N 1...

Страница 9: ...eN H f h g V Khf N Yhe V Y 7 5 W M I X e W M I X eW MeI Xe fI XfW MeI Xe3 L e 1 eJ 5 X f XfW2 5 L h N Y he W 5 g N J h W H e h Lg J 5 f e g h hV 6Khf H he V Y H W Y eV4 e 7 HfN 1 e7 H e N 1e f V X e7...

Страница 10: ...programming the controller for either the standard ON OFF mode or the PID 360EWB models mode for the modulating gas control system or On O F P d LOCK KEY DISPLAY KEY OnOF standard on off temperature...

Страница 11: ...erature condition when lit On above 650 F 343 C TEMPERATURE KEY Use to view actual oven temperature Digital Temperature Controller P N 36056 Operators Instructions HEAT ON SET PT ACTUAL TEMP SP LOCK O...

Страница 12: ...resistance reading should be in the 9 20 Ohm range Remove replace an open thermocouple 3 If the thermocouple checks good call MCSG for assistance Reverse polarity of the thermocouple leads 1 Check th...

Отзывы: