H P 2 1 0 0 / 2 7 0 0 G r e e n
P a g e
3 5
/ 4 0
Outside diameter
Torque
kgf m
inch
mm
¼
6.35
1.8
3/8
9.52
3.4
½
12.7
5.5
5/8
15.88
6.3
¾
19.05
7.0
3. Forming and insulation the piping.
The pipes must be insulation and secured
with vinyl tapes. This is done in order to
prevent condensation on the piping.
It is highly advised to place the piping into
a plastic protector when installed in the
ground (soil).
On places where piping goes throug
wall or similar it is advised to use gum type
sealer or construction foam to seal the
openings.
3.1. Condensing unit below water unit
Tape the piping and interconnecting cable
from down upwards. Fix the tapped piping
with cable binder or equivalent
exterior wall. It is important to make a trap
to prevent water from entering into the
electro installation of the condensing unit.
3.2 Condensing unit above water unit
Tape the piping and interconnecting cable
from down upwards. Fix the tapped piping
with cable binder or equivalent onto the
exterior wall. It is important to make a trap
to prevent water from entering into the
electro installation of the condensing unit.
On refrigerant side it is important to form
a syphon.
Flaring work
It is important to perform the flaring work correctly. This will have positive effect towards long
reliability and functionality of the heat pump. Defective or incorrect flaring work is the most common
cause for gas leakage. Gas leakage results in continuous decrease of heat pump efficiency and
eventually leads into security turning off, malfunction, failure or damage.
I n s t a l l a t i o n a n d u s e r m a n u a l
V e r s i o n :
Torque
kgf m
1.8-2.5
3.4-4.2
5.5-6.6
6.3-8.2
7.0-8.8
3. Forming and insulation the piping.
must be insulation and secured
with vinyl tapes. This is done in order to
prevent condensation on the piping.
It is highly advised to place the piping into
a plastic protector when installed in the
On places where piping goes through a
wall or similar it is advised to use gum type
sealer or construction foam to seal the
3.1. Condensing unit below water unit
Tape the piping and interconnecting cable
from down upwards. Fix the tapped piping
with cable binder or equivalent onto the
exterior wall. It is important to make a trap
to prevent water from entering into the
electro installation of the condensing unit.
3.2 Condensing unit above water unit
interconnecting cable
from down upwards. Fix the tapped piping
with cable binder or equivalent onto the
exterior wall. It is important to make a trap
to prevent water from entering into the
electro installation of the condensing unit.
t is important to form
It is important to perform the flaring work correctly. This will have positive effect towards long
reliability and functionality of the heat pump. Defective or incorrect flaring work is the most common
use for gas leakage. Gas leakage results in continuous decrease of heat pump efficiency and
eventually leads into security turning off, malfunction, failure or damage.
Insulation
Interconnecting cable (1
sensors, A-
Gas
Liquid
Trap
Trap
I n s t a l l a t i o n a n d u s e r m a n u a l
V e r s i o n : 0 1 / 2 0 2 1
H
E
A
T
P
U
M
P
M
I
C
R
O
W
E
L
L
H
P
It is important to perform the flaring work correctly. This will have positive effect towards long-term
reliability and functionality of the heat pump. Defective or incorrect flaring work is the most common
use for gas leakage. Gas leakage results in continuous decrease of heat pump efficiency and
Insulation
Interconnecting cable (1-4
-B-C controller)
Syphon
min.
500mm