H P 2 1 0 0 / 2 7 0 0 G r e e n
P a g e
2 3
/ 4 0
Parameter Table
NO.
Content
P0
Water pump running way
P1
Time setting ( only available when
the water pump running way is
set to “2”
P2
Compressor continuously
time in defrosting mode
P3
Defrosting start temp
P4
Defrosting running time
P5
Defrosting quit temp
P10
Compressor speed control
P12
Electronic expansion valve
overheat level
(
heating
P13
Electronic expansion valve
overheat level
(
cooling
P14
Electronic expansion valve
manual/auto
P15
Electronic expansion valve
openning setting
(
heating
P16
Electronic expansion valve
openning setting
(
cooling
P20
Power off memory function
Running status checking
Press”
” for 5 seconds, a sound of “Di” can be heard and it will enter into running status
checking, at this time, the display alternately shows status point “C0” and its corresponding value.
Change status pointer through”
Press “
” can quit “running status checking” mode
I n s t a l l a t i o n a n d u s e r m a n u a l
V e r s i o n :
Adjust range
Step length
Water pump running way
0
:
Continuation
1
:
Water temp control
2
:
micro
1
Time setting ( only available when
the water pump running way is
10 ~ 120 min
5 min
Compressor continuously running
time in defrosting mode
30 ~ 90min
1min
-17 ~ 0
℃
1
℃
Defrosting running time
1 ~ 12min
1min
8 ~ 30
℃
1
℃
Compressor speed control
0
:
Auto
,
1
:
Manual
1
expansion valve
heating
)
-10 ~ 20
1
Electronic expansion valve
cooling
)
-10 ~ 20
1
Electronic expansion valve
0
:
Auto
,
1
:
Manual
1
Electronic expansion valve
heating
)
50 ~ 240
2P
Electronic expansion valve
cooling
)
50 ~ 240
2P
Power off memory function
0 — NO
,
1 — YES
1
” for 5 seconds, a sound of “Di” can be heard and it will enter into running status
checking, at this time, the display alternately shows status point “C0” and its corresponding value.
” and “
”, the corresponding value also changes with it.
” can quit “running status checking” mode
I n s t a l l a t i o n a n d u s e r m a n u a l
V e r s i o n : 0 1 / 2 0 2 1
H
E
A
T
P
U
M
P
M
I
C
R
O
W
E
L
L
H
P
Step length
Default
0
60 min
35 min
-7
℃
12 min
13
℃
0
3
5
0
175
(
H5
)
175
(
H5
)
1
” for 5 seconds, a sound of “Di” can be heard and it will enter into running status
checking, at this time, the display alternately shows status point “C0” and its corresponding value.
”, the corresponding value also changes with it.