for swimming pool water 

Installation and user manual

 

HP1700 GREEN INVERTER 

HP 2100 GREEN

HP2700 GREEN

COMPACT

HEAT 

PUMP 

for swimming pool water 

heating & cooling 

Installation and user manual

 

 

 

HP1700 GREEN INVERTER P

RO

 

GREEN

 

INVERTER

 

P

RO

 

GREEN

 

INVERTER

 

P

RO

 

COMPACT

 

&

 

SPLIT 

Содержание Green Inverter Pro HP1100 Compact

Страница 1: ...ng pool water Installation and user manual HP1700 GREEN INVERTER HP 2100 GREEN HP2700 GREEN COMPACT HEAT PUMP for swimming pool water heating cooling Installation and user manual HP1700 GREEN INVERTER PRO GREEN INVERTER PRO GREEN INVERTER PRO COMPACT SPLIT ...

Страница 2: ... u a l H P 1 7 0 0 H P 2 1 0 0 Thank you for purchasing Microwell swimming pool heat pump Before you use this device it is necessary to carefully read the entire Installation and user manual It is not allowed to commence the heat pump installation or operation unless full content of this Installation and user manual is understood and acknowledged Please keep the Installation and user manual availa...

Страница 3: ...ON Refrigerant circuit connection Flaring work Water unit dimensions 8 1 Warranty I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n MAINTANANCE WARRANTY AND INSTALLATION I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P 32 32 33 34 35 38 39 ...

Страница 4: ... get overheated which may result in its malfunction damage or failure Do not use the product out of the designated operational air temperature range which is stated in section 3 1 Technical data The heat pump enables heat gain from the external air surrounding the swimming pool through the expansion cycles of the heat carrying liquid The air is driven by a fan through the evaporator where it will ...

Страница 5: ...ng this heat pump in the European countries the following information must be Do not dispose this product as unsorted municipal waste It is prohibited dispose this heat pump in domestic household waste It is prohibited to dispose this appliance into forests or natural landscape This could lead into local soil pollution Collection of such waste must be treated individually The municipality has esta...

Страница 6: ...lified technician When the device is not intended to be used for a longer time we recommend switching the circuit breaker of the unit s power supply off Unit must be installed in vertical position to avoid condensate water to enter electrical part of the It is forbidden to install the unit close to devices that may cause electrical or frequency disturbance such as welding machines motors or rotors...

Страница 7: ... up Heat pump will automatically defreeze itself Its operations or functionality is not harmed but the efficiency Manufacturer does not bear any responsibility concenring damages caused by inappropriate heat pump selection installation or application Do not pressurize the water heat exchanger higher than 0 25MPa 2 5bar By pressure of 0 5MPa 5bar the water heat exchanger gets irreversibly damaged I...

Страница 8: ...ven stopped Don t use or stock combustible gas or liquid such as thinners paint and fuel to avoid fire In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heater and please use a recommended cover on the swimming pool Connecting pipes of the swimming pool and the heater should be 10m Please keep the main power supply switch far...

Страница 9: ...s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n In the case of device failure resulting from improper handling or mechanical damage impact hit fall etc the manufacturer reserves the right to evaluate the continuity of warranty If so the titanium heat exchanger inside the heat pump may be damaged I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P...

Страница 10: ...CONDITION Air 27 C Water 27 C Humid 80 17 21 0 15 6 5 14 8 6 4 PERFORMANCE CONDITION Air 15 C Water 26 C Humid 70 11 5 14 5 7 8 4 6 7 1 4 6 PERFORMANCE CONDITION Air 35 C Water 28 C Humid 80 Cooling capacity kW 7 5 9 5 40 80 50 95 15 43 0 29 2 5 0 41 3 15 1 28 10 87 1 78 13 69 15 17 3X4 3X4 22 6 33 3 20 4 33 7 6 5 8 5 8 10 50 Full Stepless DC inverter compressor DC Inverter EEV Aluminium UV resist...

Страница 11: ...hey have different strengths under different Swimming pool water parameters The heat pump is designed for heating the swimming pool water Although the water heat exchanger is made from the most durable titanium in order to ensure long term reliability of the heat pump the pool water must be in accordance with the related sanitary requirements The limit values for the heat pump operation are the fo...

Страница 12: ... corrections or changes without notice 2 1 I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 Heat pump dimensions Description of the basic parts Protecting grates of the fan air outlet ventilator cover Aluminium chassis Valve for refilling the refrigerant under the cover Power supply connection underneath the metal cover Evaporator air inlet Water outlet connection hub Wate...

Страница 13: ...hine or the efficiency will be reduced or even stopped 3 The machine needs an appended pump Supplied by the user The recommended pump flux refer to Technical Parameter Max lift 10m 4 When the machine is running there will be condensation water discharged from the bottom please pay attention to it Please hold the drainage nozzle accessory into the hole and clip it well and then connect a pipe to dr...

Страница 14: ... t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 Stepless DC inverter compressor defrosting with 4 way valve efficiency twisted titanium heat exchanger High pressure and low pressure protection Soft start wide voltage application Stable inverter control system Electric wiring Diagram Connect to appropriate power supply the voltage should comply with the rated voltage Earth the ...

Страница 15: ... protecting devices and cable specification Above data is subject to modification without notice The above data is adapted to power cord 10m If power cord is 10m wire diameter must be increased The signal cable can be extended to 50m maximumly HP1700 GREEN INVERTER PRO HP2100 GREEN INVERTER PRO Rated Current A 18 0 21 0 Rated Residual Action 30 30 18 0 21 0 3 4 3 4 3 0 5 3 0 5 Distribution Box Cus...

Страница 16: ... a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P Water pump connection I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 0 0 2 7 0 0 G r e e n P a g e 1 6 4 0 ...

Страница 17: ... 2 7 0 0 G r e e n P a g e 1 7 4 0 I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P ...

Страница 18: ...l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 0 0 2 7 0 0 G r e e n P a g e 1 8 4 0 ...

Страница 19: ...r s i o n Water pump control and timer connection 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pump both 1 and 2 should be L N G P1 P2 1 2 3 4 DRY Contact On Off 5 6 HP2700 I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E...

Страница 20: ...o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 Description of the LCD panel Designation Function ON OFF Power On Off Wifi setting Unlock Heating Cooling selection Automatic heating cooling mode Heating Mode Cooling Mode Lock Unlock Screen Speed Mode Two modes for switching Max UP DOWN Temperature Setting Displaying Only light up screen and other buttons turn dark light up No display on scre...

Страница 21: ...I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n Operation Instruction for 3 seconds to lock or unlock the screen 2 Automatic Lock Period 30 seconds if no operation for 3 seconds to unlock screen Press to power on machine to display and adjust set temperature ong heating Cooling and automatic mode Heating mode Water setting range 18 40 Cooling mode Water setting range 12 30 Automati...

Страница 22: ...ter flashing enter WIFI connection Connect Wifi on mobile phone and input password then control equipment by Wifi When APP lights on 1 Active defrosting When machine is defrosting is flashing after defrosting When machine is heating and the compressor is working continuously for 10 simultaneously for 5 seconds to start forced defrosting stop flashing and defrosting stops Remarks the interval betwe...

Страница 23: ... 0 Continuation 1 Water temp control 2 microECONOMY 1 Time setting only available when the water pump running way is 10 120 min 5 min Compressor continuously running time in defrosting mode 30 90min 1min 17 0 1 Defrosting running time 1 12min 1min 8 30 1 Compressor speed control 0 Auto 1 Manual 1 expansion valve heating 10 20 1 Electronic expansion valve cooling 10 20 1 Electronic expansion valve ...

Страница 24: ...ents in corrosive environment Inspect the electric wiring on basis of the electric wiring diagram and earthing connection Double confirm the main machine power switch should be off e setting Inspect the air inlet and outlet Leakage detection notice and method Leakage checking is prohibited in closed area The ignition source is prohibited during the leakage inspection A halide torch or any other de...

Страница 25: ...e heat pump please check for any leakage of water and set suitable temperature in the thermostat and then switch on power supply In order to protect the swimming pool heater the machine is equipped with a time lag starting function the fan will run 1 minute earlier than the compressor when starting the m it will stop running 1 minute later than the compressor when power off the machine After the s...

Страница 26: ...PP Binding Please make sure you are connected to the Wi Fi Press for 3 seconds to unlock the screen press for 3 seconds then release after hearing Beep Enter Wi Fi code During connection flashes When the APP connects to the Wi Fi successfully the will display APP Download Android please download from 0 0 2 7 0 0 G r e e n P a g e 2 6 4 0 Account Registration Register by mobile or email PP Binding ...

Страница 27: ...vice I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n Click Add device and then follow instructions to pair device I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P Click Add device and then follow instructions to pair device ...

Страница 28: ...l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 0 0 2 7 0 0 G r e e n P a g e 2 8 4 0 ...

Страница 29: ... i o n a n d u s e r m a n u a l V e r s i o n swimming pool water temperature For heat pump with Heating Cooling function Max Heating Cooling 1 The weather forecast is just for reference subject to updating without notice I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P The Current swimming pool water temperature Timer Indicate the ...

Страница 30: ...er operation may cause danger Strictly comply with the manufacturer s requirements when charging R32 gas and eq maintenance This chapter focuses on special maintenance requirements for swimming pool heat pump with R32 gas Please refer to the technical service manual for detailed maintenance Vacuumize completely before welding Welding can only be carried out by professional personnel in service cen...

Страница 31: ...sor failure Cooling plate sensor failure Current sensor failure Restart memory failure Failure of the compressor drive module this is an activation of the inverter board protection it can be a unique activation as the inverter board is sensitive to fluctuations in the power supply or peaks in the network Restart the heat pump by switching the circuit breaker off and on min 60 seconds If the error ...

Страница 32: ...FC module over current protection MAINTANANCE WARRANTY In winter season when you don t swim a Cut off power supply to prevent any machine damage b Drain water clear of the machine c Cover the machine body when not in use Please clean this machine with household detergents or clean water NEVER use gasoline Check bolts cables and connections regularly If repair or scrap is required pls contact autho...

Страница 33: ... 11 Fixation holes for screws to fix the console on a wall 4x 12 Main electrical connection of the condensing unit 13 Condensing compressor unit 14 Gas R32 15 Gas R32 16 Interconnecting cable on demand 1 2 3 4 5 10 12 14 15 13 I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 0 2 1 H E A T P U M P M I C R O W E L L H P 6 Screws fixing the exchanger on console 4x 7 Electro conne...

Страница 34: ...order to operate normally This is normally done during installation of the pump as the pump comes with separate not connected condensing wise originally from the factory Refrigerant circuit must be sealed Please note that refrigerant connection can be performed by an authorized person only The person must have a valid refrigeration licence precharged with refrigerant R32 from the factory meter lon...

Страница 35: ... Forming and insulation the piping must be insulation and secured with vinyl tapes This is done in order to prevent condensation on the piping It is highly advised to place the piping into a plastic protector when installed in the On places where piping goes through a wall or similar it is advised to use gum type sealer or construction foam to seal the 3 1 Condensing unit below water unit Tape the...

Страница 36: ...tting the pipes and cables please mind the following 1 Measure the distance between the water and the condensing unit longer than measured distance 3 Cut the cable 1 5m longer than the pipe length Sometimes bits of air and moisture remains in the refrigerant circuit If this is not treated following symptoms may appear on your heat pump Pressure in the system rises Heating or cooling efficiency dro...

Страница 37: ...s have in their refrigerant circuit only 1 service valve installed Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and water unit Confirm the Lo knob of the manifold valve is open Then run the vacuum pump The operation time for evacuation varies with tubing length and capacity of the pump The following table shows the time required for evacuat...

Страница 38: ...I C R O W E L L H P Water unit dimensions A B GEPAC17 580 390 GEPAC21 650 460 GEPAC27 830 640 I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 C D E 390 55 Fi160 135 5 460 55 Fi160 135 640 55 Fi160 135 5 0 0 2 7 0 0 G r e e n P a g e 3 8 4 0 F Fi32x3 4 Fi32x3 4 Fi32x3 4 ...

Страница 39: ...arranty period and subject please refer to your local regulations and or agreement with your distributor reseller or installer Any action resulting in damage of the heat pump property or other damage caused by improper usage of this product or in contrary with this Installation and user manual is excluded from warranty coverage I n s t a l l a t i o n a n d u s e r m a n u a l V e r s i o n 0 1 2 ...

Страница 40: ...421 31 702 0540 fax 421 31 702 0542 e mail microwell microwell sk w w w m i c r o w e l l e u I n s t a l l a t i o n a n d u s e r m a n u a l H P 1 7 0 0 H P 2 1 0 0 Distributed by Manufacturer MICROWELL spol s r o SNP 2018 42 927 01 Sala Slovakia tel 421 31 702 0540 fax 421 31 702 0542 mail microwell microwell sk w w w m i c r o w e l l e u 0 0 2 7 0 0 G r e e n P a g e 4 0 4 0 ...