Microtec APD-20 Скачать руководство пользователя страница 6

- 6 -

VI. Circuit Diagram

KO: Power switch

K1: Start Switch

FU: Fuse(240V/15A, 120V/20A)

SJ: GY-04 Digital Controller

HD: Pneumatic Controller

J1: Industrial Relay

J2: Intermediate Relay Contacts

L1: Indicator Light

D: Pneumatic Valve

EH1-EH2: Heating Pipe

A-B: Thermocouple

T1(T2): AC/DC Transformer

P: Emergency Stop Button

Содержание APD-20

Страница 1: ...out Heat Press Manual Model No APD 20 24 CONTENTS I Assembly Drawing 2 II Technical Parameters 2 III Operation Process 3 4 IV Maintenance 5 V Trouble Shooting For Transfer Print Quality 5 VI Circuit D...

Страница 2: ...1 Model No APD 20 40 2 Machine Dimensions 810 410 625mm 3 Heat Platen Size 40x50cm 40x60cm 4 Printable Articles Max Size 400 600 10mm 5 Voltage 220V Single Phase 120V Single Phase 6 Power 220V 1 8KW 1...

Страница 3: ...ng your transfer If there is a difference between the actual temperature and temperature shows on the controller you can use P5 mode to calibrate the difference For example when actual heat platen tem...

Страница 4: ...irt transfer paper 10 20 seconds 3 Aluminum sheet transfer Set temperature 180 Set time 45 seconds Emergency If any emergency happens please press the red emergency stop button After settled the emerg...

Страница 5: ...ouches well 2 If the thermocouple is good It shows that the program of digital controller is broken which namely IC or is broken need to change by new controller 5 The temperature is out of control Se...

Страница 6: ...FU Fuse 240V 15A 120V 20A SJ GY 04 Digital Controller HD Pneumatic Controller J1 Industrial Relay J2 Intermediate Relay Contacts L1 Indicator Light D Pneumatic Valve EH1 EH2 Heating Pipe A B Thermoco...

Страница 7: ...7 VII Explosion View...

Страница 8: ...Electromagnet Valve 1 28 Air Hose Connector 2 29 Transformer 1 30 Solid state Relay 1 31 Electromagnetic Driver Board 1 No Part Name Qty 1 Power Cord 1 2 Fuse 1 3 Back Cover 1 4 Air Cylinder 1 5 Elect...