Microtec APD-20 Скачать руководство пользователя страница 5

IV. Maintenance

- 5 -

1. No action after turn on the machine

1). Check the plug whether it connects well or whether it is broken.
2). Check the power switch or digital controller whether it is broken.
3). Check the fuse whether it has been burnt out.
4). Indicating light is on, but no display on screen, check the 5 cable of Railway transformer. If it’s loosening,
showing the problem is poor connection. If they connects well, showing that the Transformer is faulty.

2. The display screen are working well, but no temperature increasing on the heat platen.

1). Check whether the thermocouple of the heat platen touches well. If the thermocouple is loose, the display will
show 255 and machine keeps beeping.
2). Check if the indicating light of solid-state relay is on, if not, check if the relay or digital controller is broken.
3). If you already changed the new solid-state relay but the heat platen still can’t heating up, check if the heat platen
is faulty or the heat platen’s power cable is loose, need to change by new heat platen.

3. The heat platen works well, but suddenly the display screen show 255

.

1). Check whether the thermocouple of the heat platen touches well.
2). If the thermocouple touches well but still shows 255

, then it is faulty.

4. The machine is heating during 0~180

, but display number jumps to above 200

or 300

suddenly, or

the numbers on display jumps irregularly.

1). Check whether the thermocouple of the heat platen touches well.
2). If the thermocouple is good, It shows that the program of digital controller is broken, which namely IC or is
broken, need to change by new controller.

5. The temperature is out of control: Set 180

℃,

but the actual temperature is above 200

℃。

1). It means the solid-state relay is broken, out of control, need to change the relay.
2). Or the digital controller is faulty and it keeps conveying electric to relay, need to change controller.

6. The setting temp and time becomes abnormal after exchange the heat platen

1). Please reset the temp and time according the operation process manual.

7. Other notice

1). In order to prolong the machine service life, please add the lubrication oil regularly on the joints.
2). In order to keep the heat platen's good transfer effect, you need to protect the heat platen carefully whenever
you are using it or not.
3). Please keep the machine in dry place.
4). If you are not able to solve the electrical parts problem, please kindly contact the supplier and get technical
support.

V. Trouble shooting for transfer print quality

1. If the print color is pale: the temperature is too low / the pressure is not correct / or not pressed long enough.
2. If the print color is too brown or the transfer paper is almost burnt: reduce the setting temperature
2. If the print is blurring: too much transfer time causes proliferation.
3. If print color is different/ partial transfer effect is not good enough: the pressure is not enough / or not pressed
long enough / or poor quality transfer paper.
4. If transfer paper stick to the object after transfer: the temperature is too high/ or poor quality printing ink.

Содержание APD-20

Страница 1: ...out Heat Press Manual Model No APD 20 24 CONTENTS I Assembly Drawing 2 II Technical Parameters 2 III Operation Process 3 4 IV Maintenance 5 V Trouble Shooting For Transfer Print Quality 5 VI Circuit D...

Страница 2: ...1 Model No APD 20 40 2 Machine Dimensions 810 410 625mm 3 Heat Platen Size 40x50cm 40x60cm 4 Printable Articles Max Size 400 600 10mm 5 Voltage 220V Single Phase 120V Single Phase 6 Power 220V 1 8KW 1...

Страница 3: ...ng your transfer If there is a difference between the actual temperature and temperature shows on the controller you can use P5 mode to calibrate the difference For example when actual heat platen tem...

Страница 4: ...irt transfer paper 10 20 seconds 3 Aluminum sheet transfer Set temperature 180 Set time 45 seconds Emergency If any emergency happens please press the red emergency stop button After settled the emerg...

Страница 5: ...ouches well 2 If the thermocouple is good It shows that the program of digital controller is broken which namely IC or is broken need to change by new controller 5 The temperature is out of control Se...

Страница 6: ...FU Fuse 240V 15A 120V 20A SJ GY 04 Digital Controller HD Pneumatic Controller J1 Industrial Relay J2 Intermediate Relay Contacts L1 Indicator Light D Pneumatic Valve EH1 EH2 Heating Pipe A B Thermoco...

Страница 7: ...7 VII Explosion View...

Страница 8: ...Electromagnet Valve 1 28 Air Hose Connector 2 29 Transformer 1 30 Solid state Relay 1 31 Electromagnetic Driver Board 1 No Part Name Qty 1 Power Cord 1 2 Fuse 1 3 Back Cover 1 4 Air Cylinder 1 5 Elect...

Отзывы: