Microtec APD-20 Скачать руководство пользователя страница 3

- 3 -

III. Operation Process

1. How to adjust the pressure:

1. Connect the heat press with air compressor or air sources.
2. Lift up the cap of air valve as the picture shown
3. Revolve the cap anticlockwise, the air pressure goes down; contrariwise, the air pressure goes up; when you
finish the pressure adjustment, push down the cap.
4. Suggested air pressure is 0.4~0.5Mpa/ 70-80Psi. It depends on the transfer materials.

2. Set temperature required

3. Set time required

Press

button after

temperature setting and the

time light is

on. Select with arrows the
time according to different
transfer material.

Press

button after time

setting; the display shows the
temperature starts to rise. “CD-L”
shows the time counting down
during your transfer.

If there is a difference between the actual
temperature and temperature shows on
the controller, you can use P5 mode to
calibrate the difference. For example,
when actual heat platen temperature is
180

°

C but the display shows 200

°

C,

press button for 5 seconds to enter the
P5 mode. When enter P5 mode, press
UP button

“△”

to set to- 20, and then

press button again for 5 seconds return
to operation mode. In the contrast,
when actual heat platen temperature is
200

°

C but the display shows 180

°

C,

press Down button

“▽”

to set to20, and

then press button 5 seconds return to
operation mode

Turn on power switch,
temperature light is ON. The
digital display shows

.

Press

button, the

light is

on (C denotes Celsius). Press
arrows “

” or “

” to select “

” or

” (F denotes Fahrenheit)

according to your habits.

Press

button, the temp light is on.

Select with arrows the temperature
according to different transfer material
(Normally
180

~200

)

Содержание APD-20

Страница 1: ...out Heat Press Manual Model No APD 20 24 CONTENTS I Assembly Drawing 2 II Technical Parameters 2 III Operation Process 3 4 IV Maintenance 5 V Trouble Shooting For Transfer Print Quality 5 VI Circuit D...

Страница 2: ...1 Model No APD 20 40 2 Machine Dimensions 810 410 625mm 3 Heat Platen Size 40x50cm 40x60cm 4 Printable Articles Max Size 400 600 10mm 5 Voltage 220V Single Phase 120V Single Phase 6 Power 220V 1 8KW 1...

Страница 3: ...ng your transfer If there is a difference between the actual temperature and temperature shows on the controller you can use P5 mode to calibrate the difference For example when actual heat platen tem...

Страница 4: ...irt transfer paper 10 20 seconds 3 Aluminum sheet transfer Set temperature 180 Set time 45 seconds Emergency If any emergency happens please press the red emergency stop button After settled the emerg...

Страница 5: ...ouches well 2 If the thermocouple is good It shows that the program of digital controller is broken which namely IC or is broken need to change by new controller 5 The temperature is out of control Se...

Страница 6: ...FU Fuse 240V 15A 120V 20A SJ GY 04 Digital Controller HD Pneumatic Controller J1 Industrial Relay J2 Intermediate Relay Contacts L1 Indicator Light D Pneumatic Valve EH1 EH2 Heating Pipe A B Thermoco...

Страница 7: ...7 VII Explosion View...

Страница 8: ...Electromagnet Valve 1 28 Air Hose Connector 2 29 Transformer 1 30 Solid state Relay 1 31 Electromagnetic Driver Board 1 No Part Name Qty 1 Power Cord 1 2 Fuse 1 3 Back Cover 1 4 Air Cylinder 1 5 Elect...

Отзывы: