migra Serial
Large Format, Graphics Compatible Display
Page 45
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach
+49 9681 91960-0,
+49 9681 91960-10, [email protected], www.microsyst.de
Fields marked bold are the standard settings:
Position S1
S2
S3
S4
S5
Address
LOW nibble
Address
HIGH nibble
Baud rate/
data bits/
parity
Test mode /
receiving timeout
Brightness
0
0
+0
19200 / 8 / E
aus / 30 ms
minimum
1
1
+16
1200 / 8 / N
aus / 60 ms
16 %
2
2
+32
1200 / 8 / O
aus / 90 ms
22 %
3
3
+48
1200 / 8 / E
aus / 120 ms
28 %
4
4
+64
2400 / 8 / N
aus / 150 ms
34 %
5
5
+80
2400 / 8 / O
aus / 180 ms
40 %
6
6
+96
2400 / 8 / E
aus / 210 ms
46 %
7
7
+112
4800 / 8 / N
aus / 240 ms
52 %
8
8
not
defined
4800 / 8 / O
Standard test / -
58 %
9
9
4800 / 8 / E
64 %
A
10
9600 / 8 / N
70 %
B
11
9600 / 8 / O
76 %
C
12
9600 / 8 / E
82 %
D
13
19200 / 8 / N
88 %
E
14
19200 / 8 / O
Light sensor test / -
94 %
F
15
19200 / 8 / E
off / 3...30 ms *
maximum
Switch S6 has no function.
Allowable device addresses: 1 through 126.
If a display with several controller boards is used, the following addresses are valid for
the first controller board: 1, 4, 7, 10 and so on. The remaining controller boards have
the following addresses.
Standard test
This test checks the connection between the controller and the displays.
A checkerboard must be shown if everything is all right.
Light sensor test
For adjusting the light sensor of displays for outside use.
Shows the control value of the light sensor for the display brightness (in percent).
This value is in the range of 20 % (at absolute darkness) to 100 % (at the environment
brightness, which was adjusted with the potentiometer of the brightness sensor).
The light sensor is mounted in the display housing directly behind the filter pane. By
variation of it’s potentiometer you can influence the brightness control:
Most left position:
High environment brightness is necessary to obtain a control value of 100 %.
Most right position:
Low environment brightness is necessary to obtain a control value of 100 %.