3.7.6.2 Input-dependent Macro Jump
Option A:
The macro
execution is continued at the digit „Macro no.“ („000“-„999“),
if the indicated input („0“-„F“) is equal to „0“ or „1“.
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
ESC
Function
Macro no.
hundreds
Macro no.
tens
Macro no.
ones
„E“
(fixed)
1B
h
„M“
„0“-„9“
„0“-„9“
„0“-„9“
„E“
Byte 7
Byte 8
Byte 9
No. of queried
Input (0-15)
„=“
(fixed)
queried
status (0/1)
„0“-„F“
„=“
„0“ or „1“
Option B:
The macro
execution is continued at the digit „Macro no.“ („000“-„999“), if the
indicated input was read in at least once with the status „0“ or „1“ since the
last query (with exactly this command).
The digital inputs are usually read in every 100 ms.
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
ESC
Function
Macro no.
hundreds
Macro no.
tens
Macro no.
ones
„E“
(fixed)
1B
h
„M“
„0“-„9“
„0“-„9“
„0“-„9“
„E“
Byte 7
Byte 8
Byte 9
No. of queried
Input (0-15)
„#“
(fixed)
queried
status (0/1)
„0“-„F“
„#“
„0“ or „1“
Note:
If one of these commands (option A or B) was called from within the
macro list, the next macro is executed immediately (without waiting 100
ms and without reading the digital inputs again).
After 30 of these macros („ESC-MXXXE...“) have been executed in se-
quence from within the macro list, a break of 100 ms happens and the
digital inputs are read in again.