If the bargraph is not displayed yet then this will be done now.
The bargraph-bar will be displayed corresponding to its position between
the MIN- and MAX-borders which are defined within the configuration
data. The bar always starts at the configured reference value. It ends at
the position of the current value.
At the position of the reference value the bar will be shown in its config-
ured colour.
Passing one of the colour-borders (starting at the reference value) the
bar will be shown in a new colour (defined with the border) after this
point.
Four colour-
borders are defined. Each one must be in the range „MIN-
border ... MAX-
border“:
MIN-border <= colour-border 1 <= colour-border 2 <= colour-border 3 <=
colour-border 4 <=MAX-border
The PC-software ensures this rule!
Besides showing the bargraph as a multi-coloured bar (standard), it is
also possible to show it as a single-coloured bar or as a single-coloured
mark (depending on the configuration data - see PC-software).
The colour of the single-coloured bar / mark is the same as the colour of
the end-position of the multi-coloured bar.
If the current value is not in the range „MIN-border ... MAX-border“ then
a blinking mark will be shown at the MIN- or MAX-border.