3.11 Parallel Interface
Functions can be initialised via the 16 digital inputs, which are analo-
gous to the online frames used for the serial interface.
3.11.1 Timing at the Parallels Inputs
Data Bits 1-15
Strobe
Valid Data
10%
90%
24V
24V
0V
0V
Valid Data
>110ms
>110ms
>110ms
3.11.2 Input Level at the Parallel Inputs
Level
Voltage Range
U (low)
+ 0 to 1.6 V DC
U (high)
+ 18 to 30 V DC