3-2-4. Detail Counter
The function of Detail Counter collects any information and provides the counting about
the traffic of the port, no matter the packet is good or bad.
In the Fig. 3-14, the window can show only one port counter information at the same
time. To see another port’s counter, you have to pull down the list of Select, then you will see
the figures displayed about the port you had chosen.
Each data field has 20-digit long. If the counting is overflow, the counter will be reset and
restart counting. The data is updated every time interval defined by the user. The valid range is
3 to 10 seconds. The Refresh Interval is used to set the update frequency. Default update time is
3 seconds.
Fig. 3-14
Function name:
Detail Counter
Function description:
Display the detailed counting number of each port’s traffic. In the Fig. 3-14, the window
can show all counter information of each port at one time.
Parameter description:
Rx Packets:
The counting number of the packet received.
RX Octets:
Total received bytes.
Rx High Priority Packets:
Number of Rx packets classified as high priority.