Web Interface
SERVICES Tab
Select a topic from below to learn more about the SERVICES features of the Web Interface:
SERVICES-Startup
Daemon Current State and Startup
The SyncServer uses a number services that operate continuously to support its functions.
Use this page to:
n
View the current state of the services and to turn them on or off.
n
Enable or disable services from starting automatically when the SyncServer is started.
n
Run, Reboot, or Halt the SyncServer's operating services and operating system.
Daemon
A list of the user controllable daemons supported by the SyncServer:
Web Server (HTTPD)
: Provides the SyncServer's web interface. If Auto Startup is deselected
and the SyncServer reboots, the web interface will not be available.
To start the web server after it has been stopped, open a command line session through the
Console RS-232
port located on the front panel or, if available, through a Telnet session with
LAN1 port. Once logged in, restart the web server by typing "HTTP on".
NTP
: Network Time Protocol daemon. Supports all NTP functions.
SNMP
: Simple Network Management Protocol daemon. Responds to SNMP requests and
sends SNMP traps.
SSH
: Secure Shell daemon. Provides an encrypted channel for command line sessions with
the SyncServer through the LAN1 port.
Sysplex
: Sysplex timing information on the
Sysplex Timer-Out
connector.
Time
: Time Protocol requests per RFC 868 over TCP.
Time - UDP
: Time Protocol requests per RFC 868 over UDP.
Daytime
: Daytime Protocol per RFC 867 over TCP.
Daytime - UDP
: Daytime Protocol per RFC 867 over UDP.
Telnet
: Telnet protocol service for remote access to the command line interface on LAN1.
Current State/Startup
Shows the current state of the service. To change the state, select the desired state and click
the
APPLY
button.
On:
The service is running.
Off:
The service is stopped.
Auto:
When selected, the service starts automatically when the SyncServer reboots.
Page 64
..........................................................................
997-01520-02 Rev. G2
Содержание SyncServer S200
Страница 1: ...SyncServer S200 S250 S250i User Guide Rev G2 May 2015 Part Number 997 01520 01 CD Number 998 01520 01...
Страница 2: ...Page 2...
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 78: ......
Страница 114: ......
Страница 124: ......
Страница 178: ......
Страница 182: ...Glossary Page 182 997 01520 02 Rev G2...
Страница 190: ......