Using the Other Input References
To clear site-specific information from the SyncServer, disconnect all input network cables
and GPS antenna cables from the rear of the SyncServer shortly after clicking the
APPLY
but-
ton, before the SyncServer has had time to restart.
Using the Hardware Jumper
This procedure requires:
n
A jumper.
n
Size 0 philips-head screwdriver
n
Tweezers or needle-nosed pliers for handling the jumper.
Note: Observe static protection measures while working inside the SyncServer.
To restore the factory configuration:
1. Halt the SyncServer as described in Halting the SyncServer.
2.
VERY IMPORTANT
: Remove the top cover as described in
Removing the Top Cover
(on
page 122).
3. Position a jumper (not supplied) across the jumper pins marked
JP4
, next to the circular
battery.
4. (Optional) To clear site-specific information, disconnect all network and GPS antenna
cables from the rear of the SyncServer and do not reconnect them.
5. Connect the power cable and turn the power switch on. The SyncServer restores the fact-
ory configuration.
6. After 100 seconds, turn the power switch off and disconnect the power cable.
7. Remove the jumper from the JP4 jumper pins.
8. Secure the top cover to the SyncServer using the screws.
9. Reconnect the power cable and turn the SyncServer's power on. The default factory con-
figuration has been restored.
Configuring SNMP
On the SyncServer, SNMP:
n
Responds to requests for configuration and operational information.
n
Sends traps in response to events, as configured on the
ADMIN - Alarms
page.
n
Cannot be used to change the SyncServer’s configuration (is read only).
SNMP-related pages on the SyncServer:
n
WIZARDS - SNMP:
Configure SNMP quickly (SNMP v1 and v2c only).
n
NETWORK - SNMP
: Configure SNMP and add v3 users.
n
NETWORK - SNMP Traps:
Configure trap recipients.
n
ADMIN - Alarms:
Select which events generate SNMP traps.
n
SERVICES - Startup:
Stop or start the SNMP daemon, and enable/disable it from starting
automatically when the SyncServer reboots.
Configuring the SyncServer for SNMP queries
Page 120
..........................................................................
997-01520-02 Rev. G2
Содержание SyncServer S200
Страница 1: ...SyncServer S200 S250 S250i User Guide Rev G2 May 2015 Part Number 997 01520 01 CD Number 998 01520 01...
Страница 2: ...Page 2...
Страница 4: ......
Страница 12: ......
Страница 16: ......
Страница 78: ......
Страница 114: ......
Страница 124: ......
Страница 178: ......
Страница 182: ...Glossary Page 182 997 01520 02 Rev G2...
Страница 190: ......