background image

 

 

Copyright © July, 2011

  

Microsemi 

Page 25 

Rev.A03 

Analog Mixed Signal Group 

2381 Morse Avenue, Irvine, CA  92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308 

 Multi-manager capabilities 

  Event and performance data recording 

  Runs on a PC platform with Windows graphic user 

interface (GUI) 

Содержание PowerDsine PD-RPS-1000

Страница 1: ...PowerDsine PD90XXG PD 9006G PD 9012G PD 9024G PD RPS 450 PD RPS 1000 User Guide ...

Страница 2: ... without prior notice Do not photocopy or reproduce this material without permission Disclaimer Microsemi assumes no responsibility or liability arising from the use of Midspans as described herein nor does it convey any license under its patent rights or the rights of others Applications that are described herein for any of these products are for illustrative purposes only Microsemi makes no repr...

Страница 3: ...FETY INFORMATION 6 2 1 General Guidelines 6 2 2 Warnings 6 2 3 Power Cord 7 2 4 Power Cord Specifications by Country 8 3 ABOUT THE POWER OVER ETHERNET MIDSPAN 9 3 1 10 100 1000BASE TX Ports Definition 10 3 1 1 Data Input Ports 10 3 1 2 Data and Power Output Ports 10 3 2 Indicators 11 3 2 1 Power Indicator LED 11 3 2 2 Port Indications 11 3 3 Connectors 13 4 POWER OVER ETHERNET MIDSPAN INSTALLATION...

Страница 4: ... Unit 17 5 TROUBLESHOOTING 18 5 1 Preliminary Steps 18 5 2 Troubleshooting Steps 19 6 SPECIFICATIONS 21 6 1 Physical Specifications 21 6 2 Environmental Specifications 21 6 3 Electrical Specifications 22 7 POWERDSINE S POWERVIEW PRO 24 8 POWER BACKUP AND POWER REDUNDANCY CONNECTION 26 8 1 Power Redundancy 26 8 2 Power Backup 27 8 3 Connectors 27 8 4 Connecting Backup and Redundancy Connectors 28 8...

Страница 5: ...ew Pro refer to Section 7 o F Midspan enabled full power on all ports PD RPS AAAA Redundant Power Supply Where AAAA represents available power in watts 1 2 Electrical Compatibility Approvals PowerDsine 90XXG series complies with the following standards FCC Part 15 class B with FTP cabling class A with UTP cabling EN 55022 CISPR 22 class B with FTP cabling class A with UTP cabling EN 55024 CISPR 24...

Страница 6: ... its power source Read instructions in Section 4 before connecting Midspan to Midspan power backup Midspan must use a grounded power cord as defined in Section 2 3 This product relies on the building installation for short circuit over current protection Use only a fuse or circuit breaker not higher than 15A for 120VAC U S or 10A for 230VAC international Do not work on the system connect or discon...

Страница 7: ...de of the building 2 3 Power Cord In case power cord is replaced replacement must meet local requirements To ensure a reliable connection to an AC mains supply equipment provides an appliance IEC60320 inlet used for connecting a detachable power supply cord Power socket outlet must be located near Midspan and easily accessible The only way of removing power from unit is by disconnecting the power ...

Страница 8: ...012G ACDC M PD 9012G AC PD 9006G ACDC M and PD 9006G AC The attachment plug must be an earth grounding type with a NEMA 5 15P 15A 125V or NEMA 6 15P 15A 250V configuration Denmark Supply plug must comply with section 107 2 D1 standard DK2 1a or DK2 5a Switzerland Supply plug must comply with SEV ASE 1011 France and Peru IT supplies cannot power this unit If your supplies are an IT type unit must b...

Страница 9: ... provide up to 30W or 36W in Extra Power mode according to the new PoE standard IEEE802 3at DC power is fed over the spare pairs of wires within a cable 4 5 and 7 8 to terminal units RPS family can provide backup or additional power to PD 90xxG products Power over Ethernet Midspan normally powers devices that are Power over Ethernet enabled or are equipped to receive power over Ethernet These devi...

Страница 10: ...non crossover manner straight wired These ports are designed to carry Ethernet data only Tx Rx over Standard 4 wire pairs pins 1 2 3 6 4 5 and 7 8 1000Base T 2 wire pairs pins 1 2 and 3 6 10 100Base T 3 1 2 Data and Power Output Ports Midspan has 6 12 or 24 10 100 1000Base T Data Power Out ports located on the front panel see Figure 3 1 These ports are configured in a non crossover manner straight...

Страница 11: ...Midspan and its ports Refer to Table 3 1 and Table 3 2 For details about status information during operation 3 2 1 Power Indicator LED Power Indicator LED on front panel displays power status of Power over Ethernet Midspan When this LED is illuminated in green Midspan is receiving AC power For additional information refer to Table 3 1 3 2 2 Port Indications The following sections detail PD 900XXG ...

Страница 12: ...n power supply failure disconnected or out of voltage range Unit receives backup power and continues to function normally Maintenance measures should be taken whenever possible Table 3 2 Port Status Indications PD 90xx Series Port LED Color Port Load Conditions Port Voltage Off Inactive load or unplugged port Power to port is disconnected No DC voltage present on port output lines Green Active loa...

Страница 13: ...load software Note USB connection requires CP210x Driver exe installation Supplied CD provides the driver Console port is set to 38 400 baud for managed units and 19 200 baud for unmanaged units 8 data bits no parity and 1 stop bit Figure 3 2 displays pin connections for this connector DC 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RJ IN RJ OUT Ethernet Switch PD RJ 45 RJ 45 Da...

Страница 14: ... to an Ethernet switch hub Switch s data output terminals are connected to Midspan Midspan delivers power over the spare twisted pairs pins 7 8 and pins 4 5 in PD 90xxG series of Category 5 cabling without degrading data quality Most installations require Midspan to be rack mounted Figure 4 1 Typical Installation 4 2 Verifying Kit Contents Unpack kit and verify the following items are included Pow...

Страница 15: ...k Mounting Brackets Midspan comes with 19 inch mounting brackets and screws To install Midspan into a 19 inch rack 1 Remove self adhesive rubber feet from the bottom surface 2 Install brackets using two screws per side Note Rack mounting screws are not provided Figure 4 2 Installing Mounting Brackets 4 4 Installation Factors Elevated Operating Ambient Temperature If installed in a closed or multi ...

Страница 16: ...riate consideration of equipment nameplate ratings must be given when addressing this concern Reliable Grounding Earthing Maintain reliable earthing of rack mounted equipment Pay particular attention to supply connections other than direct connections to branch circuit for example the use of power strips 4 5 Connecting Ethernet Cables Ports on Midspan s front panel are configured as Pass Through p...

Страница 17: ...er cable to receptacle AC on the back panel of the unit With power applied Midspan powers up Internal fan operates Device runs its Power On Self Test POST which takes less than 10 seconds During POST all ports are disabled and indicators illuminate in the following sequence o Port indicators and Power indicators illuminate in green o Power indicator remains lit in green port indicators are off Por...

Страница 18: ...wing sections describe troubleshooting procedures to be used if you encounter any problems with your unit 5 1 Preliminary Steps If you have a problem verify Power is applied to Midspan A crossover type Ethernet cable has not been used Ethernet cable from network is connected to DATA port Ethernet cable to PD is connected to DATA POWER port Cable pairs are attached to their corresponding ports ...

Страница 19: ...d 2 Verify voltage at power inlet is between 100 and 240 VAC 3 Remove and reapply power to device and check indicators during power up sequence A port indicator is not lit and corresponding PD does not operate 1 Verify port is enabled Midspan did not detect a PD 2 Verify PD is designed for Power over Ethernet operation 3 Verify you are using a standard Category 5 5e 6 straight wired cable with fou...

Страница 20: ...a link 1 Verify port indicator on front panel is continuously lit 2 If an external power splitter is in use replace it with a viable splitter 3 Verify that for this link you are using a standard UTP FTP Category 5 straight non crossover cabling with all four pairs and that link is 100 meters long or less 4 Try to reconnect the same PD to a different port on the same Midspan or on another one If it...

Страница 21: ...ysical Specifications Dimensions H x W x D 44 x 435 x 271 mm 1 75 x 17 2 x 10 7 P N Weight PD 9024G ACDC M F PD 9024G AC F PD RPS 1000 4 8Kg 10 6lb PD 9024G ACDC M PD 9024G AC PD 9012G ACDC M PD 9012G AC PD 9006G ACDC M PD RPS 450 4 4Kg 9 7lb PD 9006G AC 4 3Kg 9 5lb PD 90xxG DC M 2 7Kg 6lb 6 2 Environmental Specifications Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 20 to 70 C 4...

Страница 22: ...VAC at 50 60Hz Input Current 100VAC Input Current 240VAC 12A max 6A max Nominal Output Voltage 50 to 57VDC Total Output Power 864W max Maximum Output Power per Port PD 90XX series 36W Parameter PD 9024G ACDC M PD 9024G AC PD 9012G ACDC M PD 9012G AC PD RPS 450 AC Input Voltage 100 to 240 VAC at 50 60Hz Input Current 100 VAC Input Current 240 VAC 5 5A max 2 75A max Nominal Output Voltage 50 to 57 V...

Страница 23: ...nt 240VAC 4A max 2A max Total Output Power 200W max Maximum Output Power per Port 36W Nominal Output Voltage 50 to 57 VDC Parameter PD 9024G ACDC M F PD 9024G ACDC M PD 9012G ACDC M PD 9006G ACDC M PD RPS 450 PD RPS 1000 DC Input Rated Voltage 53 57 VDC Input DC Maximum Current 20A Parameter PD 9006G DC M PD 9012G DC M PD 9024G DC M DC Input Rated Voltage 46 57 VDC Input DC Maximum Current 20A Max...

Страница 24: ...f the most important features is remote power enable disable functionality on each Midspan port supporting hard resets of remote terminals such as WLAN Access Points and VoIP Phones PowerView Pro and enabling to monitor and control at network and Element levels as shown in Figure 7 1 For further details refer to PowerDsine s PowerView Web Manager user guide Figure 7 1 Management Deployment PowerVi...

Страница 25: ... Analog Mixed Signal Group 2381 Morse Avenue Irvine CA 92614 USA Phone USA 800 713 4113 ROW 949 221 7100 Fax 949 756 0308 Multi manager capabilities Event and performance data recording Runs on a PC platform with Windows graphic user interface GUI ...

Страница 26: ... provides seamless failover between two Midspans If one of the two Midspans internal power supplies fails failure is detected automatically and working power supply provides power to Midspan Both Midspans are ensured continuous uptime and all active ports continue to operate without any effect on connected powered devices Power redundancy mode is available in the following midspans PD 9024G ACDC M...

Страница 27: ...pans power supplies fails unit maintains full functionality by using an optional backup power supply Midspan Unit Redundant Power Supply PD 9024G ACDC M F PD 9524G ACDC M PD 9012G ACDC M PD RPS 1000 PD 9024G ACDC M PD 9006G ACDC M PD 55XXG ACDC M PD RPS 450 8 3 Connectors Power backup and power redundancy connectors are located on the back side of the Midspan PD 90xxG power backup and power redund...

Страница 28: ...dancy Connectors WARNING Before connecting one Midspan to another disconnect both Midspans from AC main Implement Power Backup and Power Redundancy modes by using PD RPS Cables Cable kit which includes DC Cable and RPS COM To connect the connectors 1 Verify Midspans are mounted securely on rack 2 Verify Midspans are not connected to AC mains 3 Connect DC cable two red wires two black wires and one...

Страница 29: ...t RPS COM cable 5 Connect Midspans to AC outlet 6 Verify Power Indicator LED is ON Green LED Note When connecting a midspan to midspan or to an RPS unit Connect the earth ground cable between both units Earth Ground connection Note If Power Indicator LED is not lit refer to Troubleshooting on page 18 Note RPS functionality can be monitored via NMS as described in Section 8 3 ...

Страница 30: ...nel connections 8 5 Power Backup and Power Redundancy Indications For information on NMS configuration refer to PowerView Pro user guide catalog number 056 0051 06 During Power Backup and Power Redundancy NMS View Status window displays Power Source Status field Power Source Status field shows both internal and external power supply statuses green indication for OK and red indication for Fail ...

Страница 31: ...A 800 713 4113 ROW 949 221 7100 Fax 949 756 0308 Figure 8 3 PD 90xxG View status in NMS Note Midspan provides another power fail indication via Midspan s Power Indicator LED whenever unit s internal power supply fails Power Indicator LED blinks once every second Green LED Figure 8 4 PD 90xxG Front Panel LED Indication ...

Страница 32: ...ntellectual property rights must be approved by Microsemi in writing signed by an officer of Microsemi Microsemi reserves the right to change the configuration functionality and performance of its products at anytime without any notice This product has been subject to limited testing and should not be used in conjunction with life support or other mission critical equipment or applications Microse...

Отзывы: